Tytuł pozycji:

Reproducibility of magnetization transfer ratio histogram-derived measures of the brain in healthy volunteers.

Tytuł :
Reproducibility of magnetization transfer ratio histogram-derived measures of the brain in healthy volunteers.
Autorzy :
Sormani MP; Department of Neuroscience, Scientific Institute Ospedale San Raffaele, University of Milan, Italy.
Iannucci G
Rocca MA
Mastronardo G
Cercignani M
Minicucci L
Filippi M
Pokaż więcej
Źródło :
AJNR. American journal of neuroradiology [AJNR Am J Neuroradiol] 2000 Jan; Vol. 21 (1), pp. 133-6.
Typ publikacji :
Journal Article; Research Support, Non-U.S. Gov't
Język :
English
Imprint Name(s) :
Publication: Oak Brook, IL : American Society of Neuroradiology
Original Publication: Baltimore, Williams & Wilkins.
MeSH Terms :
Magnetic Resonance Imaging*
Brain/*anatomy & histology
Adult ; Female ; Humans ; Male ; Observer Variation ; Reference Values ; Reproducibility of Results
Entry Date(s) :
Date Created: 20000211 Date Completed: 20000301 Latest Revision: 20080214
Update Code :
20210210
PMID :
10669238
Czasopismo naukowe
Using two MR scanners, we evaluated the intraobserver, interobserver, image-reimage, and interimager variabilities in the assessment of magnetization transfer ratio (MTR) histograms obtained monthly on four occasions from five healthy volunteers. With multiple observers, the mean coefficients of variations ranged from 2.2% to 8.2% for "pure" image-reimage variability, from 1.2% to 4.9% for interobserver variability, and from 2.1% to 4.9% for image-reimage variability. The mean intraobserver coefficients of variations were always lower than 1%. The mean coefficients of variations ranged from 10.2% to 14.6% for pure interimager variability and from 8.6% to 14.3% for interimager variability with multiple observers. Interimager variability accounted for 96.0% of the overall variability of average MTR, for 96.7% of peak location, and for 41.1% of the peak height. The use of different MR scanners is the main source of variability when obtaining MTR histograms.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies