Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Determination of the detective quantum efficiency of a digital x-ray detector: comparison of three evaluations using a common image data set.

Tytuł:
Determination of the detective quantum efficiency of a digital x-ray detector: comparison of three evaluations using a common image data set.
Autorzy:
Neitzel U; Philips Medical Systems, Röntgenstrasse 24, D-22335 Hamburg, Germany. />Günther-Kohfahl S
Borasi G
Samei E
Źródło:
Medical physics [Med Phys] 2004 Aug; Vol. 31 (8), pp. 2205-11.
Typ publikacji:
Comparative Study; Journal Article
Język:
English
Imprint Name(s):
Publication: 2017- : Hoboken, NJ : John Wiley and Sons, Inc.
Original Publication: Lancaster, Pa., Published for the American Assn. of Physicists in Medicine by the American Institute of Physics.
MeSH Terms:
Computer Simulation*
Models, Theoretical*
Radiographic Image Interpretation, Computer-Assisted*
X-Rays*
Entry Date(s):
Date Created: 20040921 Date Completed: 20050218 Latest Revision: 20170214
Update Code:
20240104
DOI:
10.1118/1.1766421
PMID:
15377085
Czasopismo naukowe
The detective quantum efficiency (DQE) of an x-ray digital imaging detector was determined independently by the three participants of this study, using the same data set consisting of edge and flat field images. The aim was to assess the possible variation in DQE originating from established, but slightly different, data processing methods used by different groups. For the case evaluated in this study differences in DQE of up to +/-15% compared to the mean were found. The differences could be traced back mainly to differences in the modulation transfer function (MTF) and noise power spectrum (NPS) determination. Of special importance is the inclusion of a possible low-frequency drop in MTF and the proper handling of signal offsets for the determination of the NPS. When accounting for these factors the deviation between the evaluations reduced to approximately +/-5%. It is expected that the recently published standard on DQE determination will further reduce variations in the data evaluation and thus in the results of DQE measurements.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies