Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Ventricular Arrhythmia Occurrence and Compliance in Patients Treated With the Wearable Cardioverter Defibrillator Following Percutaneous Coronary Intervention.

Tytuł:
Ventricular Arrhythmia Occurrence and Compliance in Patients Treated With the Wearable Cardioverter Defibrillator Following Percutaneous Coronary Intervention.
Autorzy:
Barraud J; Aix-Marseille University, Assistance Publique - Hôpitaux de Marseille (AP-HM), Department of Cardiology, Nord Hospital, France; Mediterranean Academic Association for Research and Studies in Cardiology (MARS Cardio), France.
Pinon P; Aix-Marseille University, Assistance Publique - Hôpitaux de Marseille (AP-HM), Department of Cardiology, Nord Hospital, France; Mediterranean Academic Association for Research and Studies in Cardiology (MARS Cardio), France.
Laine M; Aix-Marseille University, Assistance Publique - Hôpitaux de Marseille (AP-HM), Department of Cardiology, Nord Hospital, France; Mediterranean Academic Association for Research and Studies in Cardiology (MARS Cardio), France.
Cautela J; Aix-Marseille University, Assistance Publique - Hôpitaux de Marseille (AP-HM), Department of Cardiology, Nord Hospital, France; Mediterranean Academic Association for Research and Studies in Cardiology (MARS Cardio), France.
Orabona M; Aix-Marseille University, Assistance Publique - Hôpitaux de Marseille (AP-HM), Department of Cardiology, Nord Hospital, France; Mediterranean Academic Association for Research and Studies in Cardiology (MARS Cardio), France.
Koutbi L; Aix-Marseille University, Assistance Publique - Hôpitaux de Marseille (AP-HM), Department of Cardiology, Hôpital Timone, Marseille, France.
Pinto J; Aix-Marseille University, Assistance Publique - Hôpitaux de Marseille (AP-HM), Department of Cardiology, Nord Hospital, France; Mediterranean Academic Association for Research and Studies in Cardiology (MARS Cardio), France.
Thuny F; Aix-Marseille University, Assistance Publique - Hôpitaux de Marseille (AP-HM), Department of Cardiology, Nord Hospital, France; Mediterranean Academic Association for Research and Studies in Cardiology (MARS Cardio), France.
Franceschi F; Aix-Marseille University, Assistance Publique - Hôpitaux de Marseille (AP-HM), Department of Cardiology, Hôpital Timone, Marseille, France.
Paganelli F; Aix-Marseille University, Assistance Publique - Hôpitaux de Marseille (AP-HM), Department of Cardiology, Nord Hospital, France; Mediterranean Academic Association for Research and Studies in Cardiology (MARS Cardio), France.
Bonello L; Aix-Marseille University, Assistance Publique - Hôpitaux de Marseille (AP-HM), Department of Cardiology, Nord Hospital, France; Mediterranean Academic Association for Research and Studies in Cardiology (MARS Cardio), France.
Peyrol M; Aix-Marseille University, Assistance Publique - Hôpitaux de Marseille (AP-HM), Department of Cardiology, Nord Hospital, France; Mediterranean Academic Association for Research and Studies in Cardiology (MARS Cardio), France. Electronic address: .
Źródło:
Heart, lung & circulation [Heart Lung Circ] 2018 Aug; Vol. 27 (8), pp. 984-988. Date of Electronic Publication: 2017 Sep 25.
Typ publikacji:
Journal Article
Język:
English
Imprint Name(s):
Publication: : Chatswood, NSW, Australia : Elsevier Australia
Original Publication: Carlton, Vic., Australia : Blackwell Science Asia, c2000-
MeSH Terms:
Patient Compliance*
Wearable Electronic Devices*
Death, Sudden, Cardiac/*prevention & control
Electric Countershock/*instrumentation
Percutaneous Coronary Intervention/*adverse effects
Postoperative Complications/*etiology
Tachycardia, Ventricular/*etiology
Electrocardiography ; Female ; France/epidemiology ; Humans ; Incidence ; Male ; Middle Aged ; Postoperative Complications/epidemiology ; Postoperative Complications/therapy ; Retrospective Studies ; Tachycardia, Ventricular/epidemiology ; Tachycardia, Ventricular/therapy ; Ventricular Function, Left/physiology
Contributed Indexing:
Keywords: Patient compliance; Primary prevention; Remote monitoring; Sudden cardiac death; Wearable cardioverter defibrillator
Entry Date(s):
Date Created: 20171004 Date Completed: 20181016 Latest Revision: 20181016
Update Code:
20240105
DOI:
10.1016/j.hlc.2017.08.022
PMID:
28969980
Czasopismo naukowe
Background: The wearable cardioverter defibrillator (WCD) is a life-saving therapy in patients with high risk of arrhythmic death. We aimed to evaluate ventricular arrhythmia (VA) occurrence rate and compliance with the WCD during the first 90 days following myocardial revascularisation with percutaneous coronary intervention (PCI) in patients with left ventricular ejection fraction (LVEF) <30%.
Methods: From September 2015 to November 2016, clinical characteristics, WCD recordings and compliance data of the aforementioned subset of patients were prospectively collected.
Results: Twenty-four patients (men=20, 80%) were included in this analysis. Mean age was 56±10 years and mean LVEF at enrolment was 26.6±4.3%. During a mean wearing period of 3.0±1.3 months, two episodes of VA occurred in two patients (8.3%): one successfully treated with WCD shock and one with spontaneous termination. The mean and median daily use of the WCD was 21.5hours and 23.5hours a day, respectively. Eighteen patients (75%) wore the WCD more than 22hours a day.
Conclusions: The rate of VA, during the WCD period use after myocardial revascularisation with PCI, was high in our study. Otherwise it underlined that patient compliance is critical during the WCD period use. Remote monitoring and patient education are keys to achieve good compliance.
(Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.)

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies