Accuracy of the measurements from multiplanar and sagittal reconstructions of CBCT.

Tytuł:
Accuracy of the measurements from multiplanar and sagittal reconstructions of CBCT.
Autorzy:
Barreto MS; Department of Propaedeutics and Integrated Clinic, School of Dentistry, Federal University of Bahia, Salvador, Brazil.
da Silva Barbosa I; Department of Propaedeutics and Integrated Clinic, School of Dentistry, Federal University of Bahia, Salvador, Brazil.
Miranda Leite-Ribeiro P; Department of Propaedeutics and Integrated Clinic, School of Dentistry, Federal University of Bahia, Salvador, Brazil.
de Araújo TM; Department of Orthodontics, School of Dentistry, Federal University of Bahia, Salvador, Brazil.
Almeida Sarmento V; Department of Propaedeutics and Integrated Clinic, School of Dentistry, Federal University of Bahia, Salvador, Brazil.
Źródło:
Orthodontics & craniofacial research [Orthod Craniofac Res] 2020 May; Vol. 23 (2), pp. 223-228. Date of Electronic Publication: 2020 Jan 20.
Typ publikacji:
Journal Article
Język:
English
Imprint Name(s):
Original Publication: Oxford, UK : Blackwell Munksgaard, c2002-
MeSH Terms:
Spiral Cone-Beam Computed Tomography*
Cephalometry ; Cone-Beam Computed Tomography ; Imaging, Three-Dimensional ; Reproducibility of Results
References:
Kumar V, Ludlow J, Soares Cevidanes LH, Mol A. In vivo comparison of conventional and cone beam CT synthesized cephalograms. Angle Orthod. 2008;78:873-879.
Ludlow JB, Gubler M, Cevidanes L, Mol A. Precision of cephalometric landmark identification: cone-beam computed tomography vs conventional cephalometric views. Am J Orthod Dentofacial Orthop. 2009;136(3):312.e1-312.e10.
Olmez H, Gorgulu S, Akin E, Bengi AO, Tekdemir I, Ors F. Measurement accuracy of a computer-assisted three-dimensional analysis and a conventional two-dimensional method. Angle Orthod. 2011;81:375-382.
Scarfe WC, Farman AG, Sukovic P. Clinical applications of cone-beam computed tomography in dental practice. J Can Dent Assoc. 2006;72:75-80.
Ludlow JB, Timothy R, Walker C, et al. Effective dose of dental CBCT - a meta analysis of published data and additional data for nine CBCT units. Dentomaxillofac Radiol. 2015;44(1):20140197.
Gribel BF, Gribel MN, Frazão DC, McNamara JA Jr, Manzi FR. Accuracy and reliability of craniometric measurements on lateral cephalometry and 3D measurements on CBCT scans. Angle Orthod. 2011;81:26-35.
Gerlach NL, Meijer GJ, Maal TJ, et al. Reproducibility of 3 different tracing methods based on cone beam computed tomography in determining the anatomical position of the mandibular canal. J Oral Maxillofac Surg. 2010;68:811-817.
Kobayashi K, Shimoda S, Nakagawa Y, Yamamoto A. Accuracy in measurement of distance using limited cone bean computerized tomography. Int J Oral Maxillofac Implants. 2004;19:228-231.
Lascala CA, Panella J, Marques MM. Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom). Dentomaxillofac Radiol. 2004;33:291-294.
Ludlow JB, Laster WS, See M, Bailey LJ, Hershey HG. Accuracy of measurements of mandibular anatomy in cone beam computed tomography images. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2007;103:534-542.
De Vos W, Casselman J, Swennen G. Cone-beam computerized tomography (CBCT) imaging of de oral and maxillofacial region: a systematic review of the literature. Int J Oral Maxillofac Implants. 2009;38:609-625.
Sandborg M, Alm Carlsson G, Persliden J, Dance DR. Comparison of different materials for test phantoms in diagnostic radiology. Radiat Prot Dosimetry. 1993;49:345-347.
Spolyar JL. Head positioning error in cephalometric radiography - an implant study. Angle Orthod. 1987;57:77-88.
McNamara JA Jr. A method of cephalometric evaluation. Am J Orthod Dentofacial Orthop. 1984;86:449-469.
Choi JY, Choi JH, Kim NK, et al. Analysis of errors in medical rapid prototyping models. Int J Oral Maxillofac Implants. 2002;31:23-32.
Moshiri M, Scarfe WC, Hilgers ML, Scheetz JP, Silveira AM, Farman AG. Accuracy of linear measurements from imaging plate and lateral cephalometric images derived from cone-beam computed tomography. Am J Orthod Dentofacial Orthop. 2007;132:550-560.
Berco M, Rigali PH Jr, Miner RM, DeLuca S, Anderson NK, Will LA. Accuracy and reliability of linear cephalometric measurements from cone-beam computed tomography scans of a dry human skull. Am J Orthod Dentofacial Orthop. 2009;136:17.e1-17.e9.
Waitzman AA, Posnick JC, Armstrong DC, Pron GE. Craniofacial skeletal measurements based on computed tomography: part I. Accuracy and reproducibility. Cleft Palate Craniofac J. 1992;29:112-117.
Marzouqi SA, Premjani P, Vaid N, Al-Mulla A, Ferguson DJ. Evaluating the accuracy of cephalometric measurements made on hand traced 2D cephlogram, digitally traced 2D cephalogram and digitally traced 3D cephalogram from CBCT: a comparison study. Acta Sci Dent Sci. 2018;2:104-109.
Baumgaertel S, Palomo JM, Palomo L, Hans MG. Reliability and accuracy of cone- beam computed tomography dental measurements. Am J Orthod Dentofacial Orthop. 2009;136:19-25.
Waltrick KB, Nunes de Abreu Junior MJ, Junior MJ, Corrêa M, Zastrow MD, Dutra VD. Accuracy of linear measurements and visibility of the mandibular canal of cone-beam computed tomography images with different voxel sizes: an in vitro study. J Periodontol. 2013;84:68-77.
Li N, Hu B, Mi F, Song J. Preliminary evaluation of cone beam computed tomography in three-dimensional cephalometry for clinical application. Exp Ther Med. 2017;13:2451-2455.
Liberton DK, Verma P, Contratto A, Lee JS. Development and validation of novel three-dimensional craniofacial landmarks on cone-beam computed tomography scans. J Craniofac Surg. 2019;30:e611-e615.
Damstra J, Fourie Z, Huddleston Slater JJ, Ren Y. Reliability and the smallest detectable difference of measurements on 3-dimensional cone-beam computed tomography images. Am J Orthod Dentofacial Orthop. 2011;140:e107-e114.
Horner K. Radiation protection n. 172: Cone beam CT for dental and maxillofacial radiology (Evidence-based guidelines). Luxembourg: Euratom; 2012.
Primo BT, Presotto AC, De Oliveira HW, et al. Accuracy assessment of prototypes produced using multi-slice and cone-beam computed tomography. Int J Oral Maxillofac Implants. 2012;41:1291-1295.
Contributed Indexing:
Keywords: cephalometry; cone-beam computed tomography; diagnostic imaging; dimensional measurement accuracy
Entry Date(s):
Date Created: 20200101 Date Completed: 20200406 Latest Revision: 20200408
Update Code:
20240104
DOI:
10.1111/ocr.12362
PMID:
31889381
Czasopismo naukowe
Objectives: The purpose of this study was to assess the accuracy of linear measurements performed in multiplanar reconstructions (MPR) and sagittal reconstructions (SR) of the left hemiface obtained from cone-beam computed tomography (CBCT) with 3D ® Dolphin Imaging software by comparing them with the same measurements made on lateral cephalograms and on dry skulls.
Setting and Sample Population: Lateral cephalograms and CBCT (with voxels of 0.25, 0.3 and 0.4 mm) were taken of 10 dry skulls.
Materials and Methods: Linear distances were measured using the software's electronic rulers. Measurements performed on dry skulls using a digital caliper were considered the gold standard. The measurements were performed twice by two evaluators.
Results: No significant difference was found in the measurements performed with the different imaging modalities and on the dry skulls. The highest mean error was observed in the lateral cephalograms, followed by MPR and SR.
Conclusions: Cephalometric measurements performed on multiplanar and sagittal reconstructions from CBCT, with different spatial resolutions, are accurate when compared with the measurements obtained in lateral cephalograms.
(© 2019 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.)

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies