Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Two-year observation of morphologic and histopathologic changes in the monkey cornea following small incision allogenic lenticule implantation.

Tytuł:
Two-year observation of morphologic and histopathologic changes in the monkey cornea following small incision allogenic lenticule implantation.
Autorzy:
Zhao J; Department of Ophthalmology, Eye and ENT Hospital of Fudan University, NHC Key Laboratory of Myopia, Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China. Electronic address: .
Liu R; Department of Ophthalmology, Eye and ENT Hospital of Fudan University, NHC Key Laboratory of Myopia, Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China. Electronic address: .
Shen Y; Department of Ophthalmology, Eye and ENT Hospital of Fudan University, NHC Key Laboratory of Myopia, Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China. Electronic address: .
Zhang X; Department of Ophthalmology, Eye and ENT Hospital of Fudan University, NHC Key Laboratory of Myopia, Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China. Electronic address: .
Zhao Y; Department of Ophthalmology, Eye and ENT Hospital of Fudan University, NHC Key Laboratory of Myopia, Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China. Electronic address: .
Xu H; Department of Ophthalmology, Eye and ENT Hospital of Fudan University, NHC Key Laboratory of Myopia, Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China. Electronic address: .
Xu Y; Department of Ophthalmology, Eye and ENT Hospital of Fudan University, NHC Key Laboratory of Myopia, Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China. Electronic address: .
Zhou X; Department of Ophthalmology, Eye and ENT Hospital of Fudan University, NHC Key Laboratory of Myopia, Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China. Electronic address: .
Źródło:
Experimental eye research [Exp Eye Res] 2020 Mar; Vol. 192, pp. 107935. Date of Electronic Publication: 2020 Jan 16.
Typ publikacji:
Journal Article; Research Support, Non-U.S. Gov't
Język:
English
Imprint Name(s):
Publication: London : Academic Press
Original Publication: London.
MeSH Terms:
Corneal Transplantation*
Corneal Stroma/*surgery
Corneal Stroma/*transplantation
Corneal Surgery, Laser/*methods
Animals ; Corneal Stroma/diagnostic imaging ; Corneal Topography ; Follow-Up Studies ; Macaca mulatta ; Microscopy, Confocal ; Microscopy, Electron, Transmission ; Microsurgery/methods ; Refraction, Ocular/physiology ; Slit Lamp Microscopy ; Tomography, Optical Coherence ; Transplantation, Homologous ; Wound Healing/physiology
Contributed Indexing:
Keywords: Allogenic implantation; Cornea; Femtosecond laser; Lenticule; Small incision
Entry Date(s):
Date Created: 20200120 Date Completed: 20201023 Latest Revision: 20201023
Update Code:
20240104
DOI:
10.1016/j.exer.2020.107935
PMID:
31954667
Czasopismo naukowe
Purpose: To observe the morphologic and histopathologic changes of femtosecond laser assisted small incision allogenic intrastromal lenticule implantation (AILI) in monkey corneas.
Methods: 6 healthy adult monkeys were included. One eye of two monkeys and both eyes of one monkey received femtosecond lenticule extraction with a -4.0 diopter (D) correction. Each extracted refractive donor lenticule was immediately allogeneically transplanted into a corneal stromal pocket created by a femtosecond laser in another monkey's eye. A postoperative two-year follow-up was performed with slit lamp microscopy, corneal topography, anterior segment optical coherence tomography and in vivo confocal microscopy. All eyes were enucleated for Hematoxylin-Eosin staining and transmission electron microscopy (TEM) observation.
Results: No complications were observed in the follow-up period. At postoperative 2 years, the corneas remained clear and the lenticules were integrated with the surrounding tissue under slit lamp microscopy. Nerve fiber regeneration was detected in the lenticule layer as observed through confocal microscopy. Corneal power was increased by 1.83 ± 1.36 D after 2 years, which was less than at 6 months (3.27 ± 1.2 D). Disordered fibers and decreased keratocytes in the implanted lenticules could be detected under light microscopy and TEM, with a clear boundary between the lenticules and the surrounding tissue.
Conclusions: Small incision AILI is feasible and safe for reshaping the cornea. Corneal healing remained stable while refraction showed a moderate regression within postoperative 2 years.
(Copyright © 2020 Elsevier Ltd. All rights reserved.)

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies