Tytuł:
-
Efficacy and Safety of Foraminoplasty Performed Using an Endoscopic Drill to Treat Axillary Disc Herniation.
-
Autorzy:
-
He J; First Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China; Department of Orthopaedics, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China.
Tang J; Department of Orthopaedics, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China.
Jiang X; Department of Orthopaedics, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China. Electronic address: .
Ren H; Department of Orthopaedics, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China.
Cui J; Department of Orthopaedics, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China.
Liang Z; First Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China; Department of Orthopaedics, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China.
Zhang J; First Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China; Department of Orthopaedics, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China.
Liang; Department of Orthopaedics, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China.
-
Źródło:
-
World neurosurgery [World Neurosurg] 2020 Jun; Vol. 138, pp. e413-e419. Date of Electronic Publication: 2020 Mar 04.
-
Typ publikacji:
-
Journal Article
-
Język:
-
English
-
Imprint Name(s):
-
Original Publication: New York : Elsevier
-
MeSH Terms:
-
Diskectomy/*methods
Endoscopy/*methods
Foraminotomy/*methods
Intervertebral Disc Displacement/*surgery
Adult ; Diskectomy/adverse effects ; Endoscopy/adverse effects ; Female ; Foraminotomy/adverse effects ; Humans ; Intervertebral Disc Displacement/diagnostic imaging ; Magnetic Resonance Imaging ; Male ; Middle Aged ; Retrospective Studies ; Treatment Outcome
-
Contributed Indexing:
-
Keywords: Axillary disc herniation; Endoscopic drill; Foraminoplasty; Trephine
-
Entry Date(s):
-
Date Created: 20200308 Date Completed: 20200831 Latest Revision: 20200831
-
Update Code:
-
20240105
-
DOI:
-
10.1016/j.wneu.2020.02.143
-
PMID:
-
32145419
-
Objective: To evaluate the efficacy and safety of foraminoplasty using percutaneous transforaminal endoscopic discectomy (PTED) (performed with the aid of an endoscopic drill) to treat patients with axillary disc herniations.
Methods: From October 2016 to October 2018, 83 patients with single segmental axillary disc herniations diagnosed via magnetic resonance imaging who had undergone PTED were retrospectively evaluated. Of these, 38 and 45 underwent foraminoplasty using a trephine and an endoscopic drill, respectively. The 2 groups did not differ significantly in terms of age, sex, the herniated segment, the preoperative visual analog score (VAS), or the Oswestry disability index (ODI) (all P > 0.05). Foraminoplasty-related index scores were recorded.
Results: We found no significant between-group difference in the VAS and ODI scores at any time after surgery; in contrast, the scores improved significantly compared with those before surgery (both P < 0.05). Compared with the trephine group, the fluoroscopy time was shorter in the endoscopic drill group but the foraminoplasty and total operation times were longer.
Conclusions: Foraminoplasty featuring endoscopic drilling can be used to treat axillary-type lumbar disc herniations. The radiation exposure time is less than that of the trephine approach, but the drilling approach is less efficient. The short-term clinical outcomes afforded by the 2 methods do not differ.
(Copyright © 2020 Elsevier Inc. All rights reserved.)