Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Retrospective analysis of cases of intraoperative awareness in a large multi-hospital health system reported in the early postoperative period.

Tytuł:
Retrospective analysis of cases of intraoperative awareness in a large multi-hospital health system reported in the early postoperative period.
Autorzy:
Deis AS; Department of Anesthesiology & Perioperative Medicine, University of Pittsburgh Medical Center, Pittsburgh, USA.
Schnetz MP; Department of Anesthesiology & Perioperative Medicine, University of Pittsburgh Medical Center, Pittsburgh, USA.
Ibinson JW; Department of Anesthesiology & Perioperative Medicine, University of Pittsburgh School of Medicine, 3459 Fifth Avenue, UPMC Montefiore, Suite 467, Pittsburgh, PA, 15213, USA.; Clinical and Translational Science Institute, University of Pittsburgh, Pittsburgh, USA.; Department of Anesthesiology, Surgical Service Line, Veterans Affairs Pittsburgh Healthcare System, Pittsburgh, USA.
Vogt KM; Department of Anesthesiology & Perioperative Medicine, University of Pittsburgh School of Medicine, 3459 Fifth Avenue, UPMC Montefiore, Suite 467, Pittsburgh, PA, 15213, USA. .; Department of Bioengineering, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, USA. .; Center for the Neural Basis of Cognition, Pittsburgh, USA. .
Źródło:
BMC anesthesiology [BMC Anesthesiol] 2020 Mar 09; Vol. 20 (1), pp. 62. Date of Electronic Publication: 2020 Mar 09.
Typ publikacji:
Journal Article; Research Support, N.I.H., Extramural; Research Support, Non-U.S. Gov't
Język:
English
Imprint Name(s):
Original Publication: [London] : BioMed Central, 2001-
MeSH Terms:
Anesthesia, General/*methods
Electroencephalography/*methods
Intraoperative Awareness/*diagnosis
Adult ; Aged ; Female ; Hospitals ; Humans ; Intraoperative Awareness/physiopathology ; Male ; Middle Aged ; Postoperative Period ; Retrospective Studies
References:
Anesth Analg. 2015 Jan;120(1):87-95. (PMID: 25383719)
Anesthesiology. 2012 Oct;117(4):717-25. (PMID: 22990178)
Br J Anaesth. 1998 Feb;80(2):133-9. (PMID: 9602573)
Anaesthesia. 2014 Sep;69(9):969-76. (PMID: 24975139)
Anesth Analg. 2009 Feb;108(2):521-6. (PMID: 19151282)
J Neurosurg Anesthesiol. 2007 Oct;19(4):268-72. (PMID: 17893580)
Eur Rev Med Pharmacol Sci. 2013 Jul;17(13):1730-7. (PMID: 23852895)
Gen Hosp Psychiatry. 2001 Jul-Aug;23(4):198-204. (PMID: 11543846)
Chin Med J (Engl). 2011 Nov;124(22):3664-9. (PMID: 22340221)
Acta Anaesthesiol Scand. 2009 Aug;53(7):873-82. (PMID: 19496761)
Anesth Analg. 2010 Mar 1;110(3):823-8. (PMID: 19861364)
Anesthesiology. 2006 Apr;104(4):847-64. (PMID: 16571982)
Can J Anaesth. 1996 Sep;43(9):946-53. (PMID: 8874913)
Anesthesiology. 2007 Jan;106(1):26-32. (PMID: 17197842)
Br J Anaesth. 2014 Oct;113(4):549-59. (PMID: 25204697)
Br J Anaesth. 2003 Aug;91(2):170-4. (PMID: 12878613)
N Engl J Med. 2011 Aug 18;365(7):591-600. (PMID: 21848460)
Cochrane Database Syst Rev. 2016 Oct 18;10:CD007272. (PMID: 27755648)
Anesth Analg. 2009 Feb;108(2):527-35. (PMID: 19151283)
N Engl J Med. 2008 Mar 13;358(11):1097-108. (PMID: 18337600)
Br J Anaesth. 2008 Aug;101(2):178-85. (PMID: 18515816)
Br J Anaesth. 2013 Apr;110(4):501-9. (PMID: 23482998)
Anesthesiology. 2013 Dec;119(6):1275-83. (PMID: 24113645)
Lancet. 2004 May 29;363(9423):1757-63. (PMID: 15172773)
Br J Anaesth. 2015 Jul;115 Suppl 1:i20-i26. (PMID: 25735710)
Anesthesiology. 2007 Feb;106(2):269-74. (PMID: 17264720)
Anesth Analg. 2010 Mar 1;110(3):813-5. (PMID: 19713251)
Br J Anaesth. 2014 Oct;113(4):560-74. (PMID: 25204696)
Chin Med J (Engl). 2005 Jul 20;118(14):1190-4. (PMID: 16117864)
Grant Information:
K23 GM132755 United States GM NIGMS NIH HHS; MRTG-CT-2-2017 International Foundation for Anesthesia Education and Research; T32 GM075770 United States GM NIGMS NIH HHS; L30 GM120759 United States GM NIGMS NIH HHS
Contributed Indexing:
Keywords: Depth of consciousness monitoring; General anesthesia; Intraoperative awareness; Processed electroencephalogram
Entry Date(s):
Date Created: 20200311 Date Completed: 20210705 Latest Revision: 20210705
Update Code:
20240105
PubMed Central ID:
PMC7061486
DOI:
10.1186/s12871-020-00974-3
PMID:
32151241
Czasopismo naukowe
Background: Awareness with recall under general anesthesia remains a rare but important issue that warrants further study.
Methods: We present a series of seven cases of awareness that were identified from provider-reported adverse event data from the electronic anesthesia records of 647,000 general anesthetics.
Results: The low number of identified cases suggests an under-reporting bias. Themes that emerge from this small series can serve as important reminders to anesthesia providers to ensure delivery of an adequate anesthetic for each patient. Commonalities between a majority of our identified anesthetic awareness cases include: obesity, use of total intravenous anesthesia, use of neuromuscular blockade, and either a lack of processed electroencephalogram (EEG) monitoring or documented high depth of consciousness index values. An interesting phenomenon was observed in one case, where adequately-dosed anesthesia was delivered without technical issue, processed EEG monitoring was employed, and the index value suggested an adequate depth of consciousness throughout the case.
Conclusions: Provider-reported adverse event data in the immediate post-operative period are likely insensitive for detecting cases of intraoperative awareness. Though causation cannot firmly be established from our data, themes identified in this series of cases of awareness with recall under general anesthesia provide important reminders for anesthesia providers to maintain vigilance in monitoring depth and dose of anesthesia, particularly with total intravenous anesthesia.
Zaloguj się, aby uzyskać dostęp do pełnego tekstu.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies