Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

[Determination of isobutyl methacrylate in workplace air by gas chromatography].

Tytuł:
[Determination of isobutyl methacrylate in workplace air by gas chromatography].
Autorzy:
Zhang SH; Zibo Hospital for Occupational Diseases Control and Treatment, Zibo 255000, China.
Tan QT; Zibo Hospital for Occupational Diseases Control and Treatment, Zibo 255000, China.
Wang X; Zibo Hospital for Occupational Diseases Control and Treatment, Zibo 255000, China.
Źródło:
Zhonghua lao dong wei sheng zhi ye bing za zhi = Zhonghua laodong weisheng zhiyebing zazhi = Chinese journal of industrial hygiene and occupational diseases [Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi] 2020 Aug 20; Vol. 38 (8), pp. 628-630.
Typ publikacji:
Journal Article
Język:
Chinese
Imprint Name(s):
Original Publication: [Tientsin] : Tianjin shi lao dong wei sheng yan jiu suo ; Tianjin shi lao dong wei sheng huan jing yi xue hui, [1983-
MeSH Terms:
Chromatography, Gas*
Air Pollutants, Occupational/*analysis
Polymethacrylic Acids/*analysis
Carbon Disulfide ; Environmental Monitoring ; Methacrylates ; Workplace
Contributed Indexing:
Keywords: Air; Chromatography, gas; Isobutyl methacrylate; Workplace
Local Abstract: [Publisher, Chinese] 目的: 建立工作场所空气中甲基丙烯酸异丁酯的气相色谱测定方法。 方法: 于2019年7至10月,对工作场所空气中的甲基丙烯酸异丁酯采用活性炭管采集,以二硫化碳解吸后毛细管柱气相色谱法测定。 结果: 该方法测定甲基丙烯酸异丁酯在0~800 μg/ml浓度范围呈线性关系, r =0.999 93;检出限为0.35 μg/ml,最低检出浓度为0.12 mg/m(3);批内精密度为2.06%~2.72%,批间精密度为3.03%~3.83%;平均解吸效率为96.7%;穿透容量大于14.46 mg,采样效率达100%;样品在室温下至少可保存7 d。 结论: 甲基丙烯酸异丁酯的气相色谱测定方法操作简便,灵敏度高,精密度好,能准确测定空气中的甲基丙烯酸异丁酯。.
Substance Nomenclature:
0 (Air Pollutants, Occupational)
0 (Methacrylates)
0 (Polymethacrylic Acids)
9011-15-8 (poly(isobutyl methacrylate))
S54S8B99E8 (Carbon Disulfide)
Entry Date(s):
Date Created: 20200907 Date Completed: 20201028 Latest Revision: 20201028
Update Code:
20240105
DOI:
10.3760/cma.j.cn121094-20200224-00079
PMID:
32892597
Czasopismo naukowe
Objective: To establish a gas chromatography method for detecting isobutyl methacrylate in workplace air. Methods: From July to October 2019, isobutyl methacrylate in workplace air was collected by activated charcoal tube, absorbed using carbon disulfide and analyzed by gas chromatography (FID) with FFAP capillary column. Results: The linear range of isobutyl methacrylate in the method was 0-800 μg/ml, the correlation coefficient was 0.99993. The detection limit was 0.35 μg/ml. The lowest detected concentration was 0.12 mg/m(3). The within-run precision was 2.06%-2.72%, the between-run precision was 3.03%-3.83%. The rates of desorption was 96.7%. The breakthrough volume was 14.46 mg. The average sampling efficience was 100%. The samples could be stored at room temperature for 7 days. Conclusion: The method is simple, highly sensitive and precise. Isobutyl methacrylate in workplace air could be determined accurately.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies