3D cone-beam CT with a twin robotic x-ray system in elbow imaging: comparison of image quality to high-resolution multidetector CT.

Tytuł:
3D cone-beam CT with a twin robotic x-ray system in elbow imaging: comparison of image quality to high-resolution multidetector CT.
Autorzy:
Grunz JP; Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany. Grunz_.
Weng AM; Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany.
Kunz AS; Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany.
Veyhl-Wichmann M; Institute of Anatomy and Cell Biology, University of Würzburg, Koellikerstraße 6, 97070, Würzburg, Germany.
Schmitt R; Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany.
Gietzen CH; Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany.
Pennig L; Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937, Cologne, Germany.
Herz S; Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany.
Ergün S; Institute of Anatomy and Cell Biology, University of Würzburg, Koellikerstraße 6, 97070, Würzburg, Germany.
Bley TA; Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany.
Gassenmaier T; Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080, Würzburg, Germany.
Źródło:
European radiology experimental [Eur Radiol Exp] 2020 Sep 08; Vol. 4 (1), pp. 52. Date of Electronic Publication: 2020 Sep 08.
Typ publikacji:
Journal Article; Research Support, Non-U.S. Gov't
Język:
English
Imprint Name(s):
Original Publication: [London, United Kingdom] : SpringerOpen, [2017]-
MeSH Terms:
Imaging, Three-Dimensional*
Multidetector Computed Tomography*
Cone-Beam Computed Tomography/*instrumentation
Elbow/*diagnostic imaging
Robotics/*instrumentation
Cadaver ; Humans
References:
Skeletal Radiol. 2015 Aug;44(8):1111-7. (PMID: 25761727)
Dentomaxillofac Radiol. 2008 Mar;37(3):137-41. (PMID: 18316504)
AJR Am J Roentgenol. 2020 Feb;214(2):422-427. (PMID: 31799871)
J Chiropr Med. 2016 Jun;15(2):155-63. (PMID: 27330520)
Injury. 2015 Jul;46 Suppl 2:S14-8. (PMID: 26026203)
AJNR Am J Neuroradiol. 2009 Aug;30(7):1285-92. (PMID: 19461061)
Eur Radiol. 2017 Feb;27(2):790-800. (PMID: 27169574)
Clin Oral Implants Res. 2010 Nov;21(11):1201-8. (PMID: 21039890)
EFORT Open Rev. 2018 May 21;3(5):278-286. (PMID: 29951267)
Radiographics. 2013 May;33(3):869-88. (PMID: 23674780)
AJR Am J Roentgenol. 2013 Jan;200(1):146-8. (PMID: 23255755)
Biomed Tech (Berl). 2010 Dec;55(6):361-5. (PMID: 20939693)
Insights Imaging. 2018 Feb;9(1):35-45. (PMID: 29302798)
Surg Radiol Anat. 2018 Jan;40(1):31-37. (PMID: 28828519)
Br J Radiol. 2016;89(1058):20150687. (PMID: 26577438)
Bone Joint J. 2016 Dec;98-B(12):1668-1673. (PMID: 27909130)
Eur J Radiol. 2019 Oct;119:108659. (PMID: 31520930)
Radiology. 2014 Mar;270(3):816-24. (PMID: 24475803)
PLoS One. 2016 Oct 27;11(10):e0164859. (PMID: 27788215)
Eur Radiol. 2015 Jun;25(6):1742-51. (PMID: 25599933)
Dentomaxillofac Radiol. 2011 Jul;40(5):265-73. (PMID: 21697151)
Br J Radiol. 2009 Jan;82(973):35-40. (PMID: 18852212)
Skeletal Radiol. 2010 Nov;39(11):1087-95. (PMID: 20224906)
Grant Information:
Z-2/CSP-06 International Interdisziplinäres Zentrum für Klinische Forschung, Universitätsklinikum Würzburg
Contributed Indexing:
Keywords: Cancellous bone; Cone-beam computed tomography; Elbow; Elbow joint; Multidetector computed tomography
Entry Date(s):
Date Created: 20200908 Date Completed: 20210705 Latest Revision: 20210705
Update Code:
20240105
PubMed Central ID:
PMC7477066
DOI:
10.1186/s41747-020-00177-y
PMID:
32895778
Czasopismo naukowe
Background: Elbow imaging is challenging with conventional multidetector computed tomography (MDCT), while cone-beam CT (CBCT) provides superior options. We compared intra-individually CBCT versus MDCT image quality in cadaveric elbows.
Methods: A twin robotic x-ray system with new CBCT mode and a high-resolution clinical MDCT were compared in 16 cadaveric elbows. Both systems were operated with a dedicated low-dose (LD) protocol (equivalent volume CT dose index [CTDI vol(16 cm) ] = 3.3 mGy) and a regular clinical scan dose (RD) protocol (CTDI vol(16 cm) = 13.8 mGy). Image quality was evaluated by two radiologists (R1 and R2) on a seven-point Likert scale, and estimation of signal intensity in cancellous bone was conducted. Wilcoxon signed-rank tests and intraclass correlation coefficient (ICC) statistics were used.
Results: The CBCT prototype provided superior subjective image quality compared to MDCT scans (for RD, p ≤ 0.004; for LD, p ≤ 0.001). Image quality was rated very good or excellent in 100% of the cases by both readers for RD CBCT, 100% (R1) and 93.8% (R2) for LD CBCT, 62.6% and 43.8% for RD MDCT, and 0.0% and 0.0% for LD MDCT. Single-measure ICC was 0.95 (95% confidence interval 0.91-0.97; p < 0.001). Software-based assessment supported subjective findings with less "undecided" pixels in CBCT than dose-equivalent MDCT (p < 0.001). No significant difference was found between LD CBCT and RD MDCT.
Conclusions: In cadaveric elbow studies, the tested cone-beam CT prototype delivered superior image quality compared to high-end multidetector CT and showed a potential for considerable dose reduction.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies