Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

A sensitive HPLC-DMS/MS/MS method for multiplex analysis of androgens in human serum without derivatization and its application to PCOS patients.

Tytuł:
A sensitive HPLC-DMS/MS/MS method for multiplex analysis of androgens in human serum without derivatization and its application to PCOS patients.
Autorzy:
Zhang X; Department of Pharmacy, Peking University Third Hospital, Beijing 100191, PR China.
Zhou C; Department of Pharmacy, Peking University Third Hospital, Beijing 100191, PR China.
Xu H; Reproductive Medicine Center, Peking University Third Hospital, Beijing 100191, PR China.
Feng Y; Reproductive Medicine Center, Peking University Third Hospital, Beijing 100191, PR China.
Yang P; Department of Pharmacy, Peking University Third Hospital, Beijing 100191, PR China.
Zhai S; Department of Pharmacy, Peking University Third Hospital, Beijing 100191, PR China.
Song J; Reproductive Medicine Center, Peking University Third Hospital, Beijing 100191, PR China.
Yang L; Department of Pharmacy, Peking University Third Hospital, Beijing 100191, PR China. Electronic address: .
Źródło:
Journal of pharmaceutical and biomedical analysis [J Pharm Biomed Anal] 2021 Jan 05; Vol. 192, pp. 113680. Date of Electronic Publication: 2020 Oct 13.
Typ publikacji:
Journal Article
Język:
English
Imprint Name(s):
Publication: <2006->: London : Elsevier Science
Original Publication: Oxford ; New York : Pergamon Press, c1983-
MeSH Terms:
Androgens*
Polycystic Ovary Syndrome*
Chromatography, High Pressure Liquid ; Female ; Humans ; Reproducibility of Results ; Spectrum Analysis ; Tandem Mass Spectrometry
Contributed Indexing:
Keywords: 11-Oxygenated androgens; Classical androgens; HPLC-DMS/MS/MS; Human serum; PCOS
Substance Nomenclature:
0 (Androgens)
Entry Date(s):
Date Created: 20201029 Date Completed: 20210617 Latest Revision: 20210617
Update Code:
20240105
DOI:
10.1016/j.jpba.2020.113680
PMID:
33120306
Czasopismo naukowe
Both classical androgens and 11-oxygenated androgens play important roles in polycystic ovarian syndrome (PCOS). Therefore, high-quality measurements of androgens are very important. In the present study, a highly sensitive and specific method was developed and validated for the simultaneous determination of three classical androgens and five 11-oxygenated androgens in human serum, using a high- performance liquid chromatography-differential mobility spectrometry tandem mass spectrometry (HPLC-DMS/MS/MS). Serum samples were extracted with the mixture of ethyl acetate/tert-butyl methyl ether (1/1, v/v) prior to analysis with the HPLC-DMS/MS/MS system. Stable isotopes were used as the internal standards. Separation was performed on a Poroshell SB C18 column (150 × 2.1 mm, 2.7 μm), with a differential mobility spectrometry (DMS) component, which was used to enhance the resolution. The gradient mobile phase consisted of acetonitrile and ammonium formate buffer with 0.1 % formic acid in both solvents. The sensitivity of the majority of the androgens was improved following addition of the DMS component. Under the optimal conditions, the trace amount of the target androgens in the serum was quantified accurately. The lower limit of quantification of the different analytes ranged from 0.05 to 0.2 ng/mL. The method was validated prior to its application to the assay of the clinical samples.
Competing Interests: Declaration of Competing Interest The authors report no declarations of interest.
(Copyright © 2020 Elsevier B.V. All rights reserved.)

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies