Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Comparison of Procedural and 1-Year Clinical Results of Transcatheter Aortic Valve Implantation Using Prostheses with Different Design of Support Frame.

Tytuł:
Comparison of Procedural and 1-Year Clinical Results of Transcatheter Aortic Valve Implantation Using Prostheses with Different Design of Support Frame.
Autorzy:
Li F; Department of Structural Heart Disease, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College.; Department of Magnetic Resonance Imaging, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College.
Wang X; Department of Structural Heart Disease, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College.
Wang Y; Department of Structural Heart Disease, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College.
Li X; Department of Structural Heart Disease, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College.
Xu D; Department of Structural Heart Disease, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College.
Zhao S; Department of Magnetic Resonance Imaging, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College.
Wang C; Department of Cardiovascular Surgery, Shanghai Cardiovascular Institution and Zhongshan Hospital, Fudan University.
Guo Y; Department of Cardiovascular Surgery, West China Hospital, Sichuan University.
Wu Y; Department of Structural Heart Disease, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College.
Wang W; Department of Structural Heart Disease, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College.
Źródło:
International heart journal [Int Heart J] 2020 Nov 28; Vol. 61 (6), pp. 1196-1203. Date of Electronic Publication: 2020 Nov 13.
Typ publikacji:
Comparative Study; Journal Article
Język:
English
Imprint Name(s):
Original Publication: [Tokyo, Japan] : International Heart Journal Association, [2005]-
MeSH Terms:
Heart Valve Prosthesis*
Pacemaker, Artificial*
Prosthesis Design*
Transcatheter Aortic Valve Replacement*
Aortic Valve Stenosis/*surgery
Atrioventricular Block/*epidemiology
Postoperative Complications/*epidemiology
Aged ; Aged, 80 and over ; Aortic Valve Stenosis/complications ; Atrioventricular Block/therapy ; Bicuspid Aortic Valve Disease/complications ; Bicuspid Aortic Valve Disease/surgery ; Cardiac Pacing, Artificial ; Conversion to Open Surgery/statistics & numerical data ; Echocardiography ; Female ; Humans ; Male ; Postoperative Complications/therapy ; Retrospective Studies ; Stroke Volume ; Treatment Outcome
Contributed Indexing:
Keywords: Permanent pacemaker implantation; Transaortic pressure gradient; Transcatheter heart valve
Entry Date(s):
Date Created: 20201116 Date Completed: 20201221 Latest Revision: 20201221
Update Code:
20240105
DOI:
10.1536/ihj.20-398
PMID:
33191360
Czasopismo naukowe
Our study aimed to investigate whether the frame design of transcatheter heart valve (THV) affects the procedural and clinical results of transcatheter aortic valve implantation (TAVI).We retrospectively reviewed 163 patients with aortic stenosis who underwent TAVI using different types of THV (Edwards SAPIEN, n = 31; Venus-A, n = 63; and J-Valve, n = 69). The procedural outcomes and follow-up results for 1-year were compared among groups.The patients who underwent TAVI using J-Valve had a higher mean transaortic pressure gradient than those using SAPIEN or Venus-A after TAVI (1-year follow-up; P = 0.017, P < 0.001, respectively), whereas no difference was observed between the patients with SAPIEN and Venus-A prosthesis (P = 0.150). The incidence of permanent pacemaker implantation was highest in patients with Venus-A (19.0%), followed by SAPIEN (9.7%), and lowest in J-Valve (4.3%) (P = 0.025). No difference was observed in the 30-day mortality rate among the groups (P = 1.000). Moreover, Kaplan-Meier survival analysis revealed that there was no significant difference in the 1-year cumulative patient survival rate among three patient cohorts (log-rank, P = 0.850).The frame design of THVs could affect the valve-related hemodynamics and the incidence of permanent pacemaker implantation in TAVI, whereas it did not influence the survival rate of TAVI patients during 1-year follow-up period. All three THVs provided a convincing short-term outcome for TAVI patients.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies