Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Abdominal Stiffness Evaluation in Massage for Constipation.

Tytuł:
Abdominal Stiffness Evaluation in Massage for Constipation.
Autorzy:
Wang Y; Graduated School of Natural Science and Technology, Kanazawa University, Kakuma-machi, Kanazawa 920-1192, Japan.
Sakakibara C; Home-Visit Nursing Care Station Yayanoie, 88 Suehiro, Komatsu 923-0954, Japan.
Shogenji M; Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa 920-0942, Japan.
Yoshida M; Department of Women's Health Nursing & Midwifery, Tohoku University Graduate School of Medicine, Sendai 980-8575, Japan.
Watanabe T; Faculty of Frontier Engineering, Institute of Science and Engineering, Kanazawa University, Kakuma-machi, Kanazawa 920-1192, Japan.
Źródło:
Sensors (Basel, Switzerland) [Sensors (Basel)] 2021 Feb 08; Vol. 21 (4). Date of Electronic Publication: 2021 Feb 08.
Typ publikacji:
Journal Article
Język:
English
Imprint Name(s):
Original Publication: Basel, Switzerland : MDPI, c2000-
MeSH Terms:
Constipation*/diagnosis
Massage*
Abdomen/physiology ; Humans ; Wearable Electronic Devices
References:
PLoS One. 2014 Aug 22;9(8):e105281. (PMID: 25148393)
J Clin Gastroenterol. 1995 Jan;20(1):61-70. (PMID: 7884183)
J Mech Behav Biomed Mater. 2017 Oct;74:411-427. (PMID: 28692907)
Ultrasound Med Biol. 2019 Apr;45(4):902-912. (PMID: 30665723)
J Biomech. 2011 Feb 24;44(4):600-6. (PMID: 21130459)
Ultrasound Med Biol. 2016 Apr;42(4):1018-25. (PMID: 26746381)
BMJ. 1990 Feb 17;300(6722):439-40. (PMID: 2107897)
J Integr Med. 2017 Mar;15(2):142-150. (PMID: 28285619)
Sensors (Basel). 2017 Nov 21;17(11):. (PMID: 29160821)
Forsch Komplementarmed. 1999 Jun;6(3):149-51. (PMID: 10460984)
Acta Radiol. 2011 Feb 1;52(1):99-105. (PMID: 21498334)
IEEE Trans Ultrason Ferroelectr Freq Control. 2004 Aug;51(8):980-9. (PMID: 15346586)
Colorectal Dis. 2013 May;15(5):e250-5. (PMID: 23375005)
Healthcare (Basel). 2018 May 25;6(2):. (PMID: 29799515)
J Korean Acad Nurs. 2011 Feb;41(1):110-8. (PMID: 21516005)
Sensors (Basel). 2019 Sep 06;19(18):. (PMID: 31500135)
IEEE Trans Biomed Eng. 2008 Mar;55(3):1230-2. (PMID: 18334419)
J Clin Nurs. 2012 Mar;21(5-6):757-65. (PMID: 22098585)
Int J Nurs Stud. 2009 Jun;46(6):759-67. (PMID: 19217105)
Biomed Res Int. 2017;2017:1854027. (PMID: 28642870)
Gastroenterol Nurs. 2018 Sep/Oct;41(5):396-402. (PMID: 30272602)
Gastroenterology. 2013 Jan;144(1):218-38. (PMID: 23261065)
Mult Scler. 2011 Feb;17(2):223-33. (PMID: 20940182)
J Altern Complement Med. 2014 Jun;20(6):507-15. (PMID: 23700977)
Abdom Imaging. 2015 Apr;40(4):745-59. (PMID: 25488346)
Grant Information:
Top Down Project Kanazawa University
Contributed Indexing:
Keywords: abdominal massage; abdominal stiffness; stiffness sensor
Entry Date(s):
Date Created: 20210211 Date Completed: 20210226 Latest Revision: 20210303
Update Code:
20240105
PubMed Central ID:
PMC7915621
DOI:
10.3390/s21041192
PMID:
33567621
Czasopismo naukowe
According to the experience of nurses and physiotherapists, the abdomen of constipated people becomes softer after abdominal massage. However, the relationship between the decrease in abdominal stiffness and the benefits of abdominal massage has not been examined quantitatively and is unclear. Furthermore, devices for measuring stiffness have been designed to measure relatively hard areas such as the shoulders and do not take into account the lateral outflow of the target tissue, which can be a problem when measuring the stiffness of soft areas such as the abdomen. To address these issues, this study presents a stiffness sensor suitable for measuring abdominal stiffness and investigates the relationship between the reduction in abdominal stiffness and the benefits of abdominal massage. The solution to prevent the lateral outflow of the target is the realization of a stopper, including a contact detection device, which enables a wide-area contact around the targeted area. The sensor consists of a stopper, probe, spring, and time-of-flight (ToF) sensors. The probe and spring provide appropriate pressure and deformation to the abdomen, whereas the stopper prevents the probe from being pushed into the abdomen more than necessary. The ToF sensor measures the deformation length when the deformation is stopped by the stopper. The abdominal stiffness can be derived from the deformation length. The investigation results indicate that the reduction in abdominal stiffness corresponds to the improvement of the stool condition or the maintenance of a healthy stool condition, whereas the maintenance of abdominal stiffness indicates the maintenance or deterioration of the stool condition.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies