Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Advances in the evaluation of sample adequacy during endoscopic ultrasound-guided tissue acquisition.

Tytuł:
Advances in the evaluation of sample adequacy during endoscopic ultrasound-guided tissue acquisition.
Autorzy:
Ashida R; Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan.
Kitano M; Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan.
Źródło:
Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society [Dig Endosc] 2021 Sep; Vol. 33 (6), pp. 927-928. Date of Electronic Publication: 2021 Aug 16.
Typ publikacji:
Editorial
Język:
English
Imprint Name(s):
Publication: 2019- : Richmond, Vic., Australia : John Wiley & Sons Australia, Ltd.
Original Publication: Tokyo, Japan : The Society, c1989-
MeSH Terms:
Endosonography*
Pancreatic Neoplasms*
Endoscopic Ultrasound-Guided Fine Needle Aspiration ; Humans
References:
Madhoun MF, Wani SB, Rastogi A et al. The diagnostic accuracy of 22-gauge and 25-gauge needles in endoscopic ultrasound-guided fine needle aspiration of solid pancreatic lesions: a meta-analysis. Endoscopy 2013; 45: 86-92.
Matynia AP, Schmidt RL, Barraza G, Layfield LJ, Siddiqui AA, Adler DG. Impact of rapid on-site evaluation on the adequacy of endoscopic-ultrasound guided fine-needle aspiration of solid pancreatic lesions: A systematic review and meta-analysis. J Gastroenterol Hepatol 2014; 29: 697-705.
Schmidt RL, Walker BS, Howard K, Layfield LJ, Adler DG. Rapid on-site evaluation reduces needle passes in endoscopic ultrasound-guided fine-needle aspiration for solid pancreatic lesions: A risk-benefit analysis. Dig Dis Sci 2013; 58: 3280-6.
Khan MA, Grimm IS, Ali B et al. A meta-analysis of endoscopic ultrasound-fine-needle aspiration compared to endoscopic ultrasound-fine-needle biopsy: Diagnostic yield and the value of onsite cytopathological assessment. Endosc Int Open 2017; 5: E363-75.
Hayashi T, Ishiwatari H, Yoshida M et al. Rapid on-site evaluation by endosonographer during endoscopic ultrasound-guided fine needle aspiration for pancreatic solid masses. J Gastroenterol Hepatol 2013; 28: 656-63.
Savoy AD, Raimondo M, Woodward TA et al. Can endosonographers evaluate on-site cytologic adequacy? A comparison with cytotechnologists. Gastrointest Endosc 2007; 65: 953-7.
Iwashita T, Yasuda I, Mukai T et al. Macroscopic on-site quality evaluation of biopsy specimens to improve the diagnostic accuracy during EUS-guided FNA using a 19-gauge needle for solid lesions: A single-center prospective pilot study (MOSE study). Gastrointest Endosc 2015; 81: 177-85.
Mangiavillano B, Frazzoni L, Togliani T et al. Macroscopic on-site evaluation (MOSE) of specimens from solid lesions acquired during EUS-FNB: Multicenter study and comparison between needle gauges. Endosc Int Open 2021; 9: E901-6.
Arena M, Eusebi LH, Pellicano R et al. Endoscopic ultrasound core needle for diagnosing of solid pancreatic lesions: Is rapid on-site evaluation really necessary? Minerva Med 2017; 108: 547-53.
Matsumoto K, Hara K, Yasuda I et al. Usefulness of a target sample check illuminator in the detection of target specimens in endoscopic ultrasound-guided fine-needle biopsy samples: Multicenter prospective study. Dig Endosc 2021; 33: 970-6.
Entry Date(s):
Date Created: 20210816 Date Completed: 20210910 Latest Revision: 20210910
Update Code:
20240105
DOI:
10.1111/den.14093
PMID:
34397146
Opinia redakcyjna

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies