Comparison of intraocular pressure in healthy brachycephalic and nonbrachycephalic cats using the Icare® TONOVET Plus rebound tonometer.

Tytuł:
Comparison of intraocular pressure in healthy brachycephalic and nonbrachycephalic cats using the Icare® TONOVET Plus rebound tonometer.
Autorzy:
Kerdchuchuen K; Faculty of Veterinary Science, Chulalongkorn University, Bangkok, Thailand.
Samathayanon K; Faculty of Veterinary Science, Chulalongkorn University, Bangkok, Thailand.
Phientong P; Faculty of Veterinary Science, Chulalongkorn University, Bangkok, Thailand.
Chattraphirat S; Faculty of Veterinary Science, Chulalongkorn University, Bangkok, Thailand.
Jaturakan O; Faculty of Veterinary Science, Chulalongkorn University, Bangkok, Thailand.
Tuntivanich N; Faculty of Veterinary Science, Chulalongkorn University, Bangkok, Thailand.
Źródło:
Veterinary ophthalmology [Vet Ophthalmol] 2021 Sep; Vol. 24 (5), pp. 484-490. Date of Electronic Publication: 2021 Sep 06.
Typ publikacji:
Clinical Trial, Veterinary; Journal Article
Język:
English
Imprint Name(s):
Original Publication: Osney Mead, Oxford, UK : Blackwell Science, c1998-
MeSH Terms:
Intraocular Pressure*
Craniosynostoses/*veterinary
Tonometry, Ocular/*veterinary
Animals ; Cats ; Craniosynostoses/physiopathology ; Female ; Male ; Tonometry, Ocular/instrumentation
References:
Emmerson T. Brachycephalic obstructive airway syndrome: a growing problem. J Small Anim Pract. 2014;55(11):543-544.
Lyons LA. DNA mutations of the cat: the good, the bad and the ugly. J Feline Med Surg. 2015;17(3):203-219.
Bertolini F, Gandolfi B, Kim ES, Haase B, Lyons LA, Rothschild MF. Evidence of selection signatures that shape the Persian cat breed. Mamm Genome. 2016;27(3-4):144-155.
Schmidt MJ, Kampschulte M, Enderlein S, et al. The relationship between brachycephalic head features in modern persian cats and dysmorphologies of the skull and internal hydrocephalus. J Vet Intern Med. 2017;31(5):1487-1501.
Schlueter C, Budras KD, Ludewig E, et al. Brachycephalic feline noses: CT and anatomical study of the relationship between head conformation and the nasolacrimal drainage system. J Feline Med Surg. 2009;11(11):891-900.
Blocker T, van der Woerdt A. A comparison of corneal sensitivity between brachycephalic and Domestic Short-haired cats. Vet Ophthalmol. 2001;4(2):127-130.
Farnworth MJ, Chen R, Packer RM, Caney SM, Gunn-Moore DA. Flat feline faces: is brachycephaly associated with respiratory abnormalities in the domestic cat (Felis catus)? PLoS One. 2016;11(8):e0161777.
Brooks DE. Glaucoma in the dog and cat. Vet Clin North Am Small Anim Pract. 1990;20(3):775-797.
Blocker T, Van Der Woerdt A. The feline glaucomas: 82 cases (1995-1999). Vet Ophthalmol. 2011;4(2):81-85.
Jacobi S, Dubielzig RR. Feline primary open angle glaucoma. Vet Ophthalmol. 2008;11(3):162-165.
Dubielzig R, Ketring K, McLellan G, Albert D. Veterinary Ocular Pathology: A Comparative Review. Saunders Elsevier; 2010:419-448.
McLellan GJ, Teixeira LB. Feline glaucoma. Vet Clin North Am Small Anim Pract. 2015;45(6):1307-1333.
McLellan GJ, Miller PE. Feline glaucoma-a comprehensive review. Vet Ophthalmol. 2011;14:15-29.
Miller PE, Pickett JP. Comparison of the human and canine Schiotz tonometry conversion tables in clinically normal cats. J Am Vet Med Assoc. 1992;201(7):1017-1020.
Ogbuehi KC, Chijuka JC, Osuagwu UL. Two-position measurement of intraocular pressure by PT 100 noncontact tonometry in comparison with Goldmann tonometry. Clin Ophthalmol. 2011;5:1227-1234.
Ricci CL, Giuffrida R, Kanashiro GP, et al. Ex vivo and in vivo study of Kowa HA-2 applanation tonometer in the measurement of intraocular pressure in cats. Semina. 2017;38(6):3647-3656.
McLellan GJ, Kemmerling JP, Kiland JA. Validation of the TonoVet(R) rebound tonometer in normal and glaucomatous cats. Vet Ophthalmol. 2013;16(2):111-118.
Andrade SF, Cremonezi T, Zachi CA. Evaluation of the Perkins handheld applanation tonometer in the measurement of intraocular pressure in dogs and cats. Vet Ophthalmol. 2009;12(5):277-284.
Andrade SF, Palozzi RJ, Giuffrida R. Comparison of intraocular pressure measurement between the Tono-Pen XL and Perkins applanation tonometers in dogs and cats. Vet Ophthalmol. 2012;15(supplement 1):14-20.
Kontiola AI. A new induction-based impact method for measuring intraocular pressure. Acta Ophthalmol Scand. 2000;78(2):142-145.
Zakrzewska A, Wiącek MP, Machalinska A. Impact of corneal parameters on intraocular pressure measurements in different tonometry methods. Int J Ophthalmol. 2019;12:1853-1858.
Smith L. Tonometry. Ocular Outlook. 2012;10(3):1-2.
Rusanen E, Florin M, Hässig M, Spiess BM. Evaluation of a rebound tonometer (Tonovet®) in clinically normal cat eyes. Vet Ophthalmol. 2010;13(1):31-36.
Minella AL, Kiland JA & McLellan GJ Validation of the Tonovet Plus® and Tono- Pen Avia™ tonometers in normal canine eyes. In: Abstracts: The 49Th Annual Scientific Meeting of The American College of Veterinary Ophthalmologists. 2018; Minneapolis: Minnesota.
Gloe S, Rothering A, Kiland JA, McLellan GJ. Validation of the Icare® TONOVET plus rebound tonometer in normal rabbit eyes. Exp Eye Res. 2019;185:1-4.
Minella AL, Kiland JA, Gloe S, McLellan GJ. Validation and comparison of four handheld tonometers in normal ex vivo canine eyes. Vet Ophthalmol. 2020;24:1-9. https://doi.org/10.1111/vop.12780.
Shim J, Kang S, Park Y. Comparative intraocular pressure measurements using three different rebound tonometers through in an ex vivo analysis and clinical trials in canine eyes. Vet Ophthalmol. 2020;24:1-8. https://doi.org/10.1111/vop.12771.
Knollinger AM, La Croix NC, Barrett PM, Miller PE. Evaluation of a rebound tonometer for measuring intraocular pressure in dogs and horses. J Am Vet Med Assoc. 2005;227(2):244-248.
Elsmo EJ, Kiland JA, Kaufman PL, McLellan GJ. Evaluation of rebound tonometry in non-human primates. Exp Eye Res. 2011;92(4):268-273.
Kroll MM, Miller PE, Rodan IJ. Intraocular pressure measurements obtained as part of a comprehensive geriatric health examination from cats seven years of age or older. J Am Vet Med Assoc. 2001;219(10):1406-1410.
Ofri R, Shub N, Galin Z, Shemesh M, Shore LS. Effect of reproductive status on intraocular pressure in cats. J Am Vet Med Assoc. 2002;63(2):159-162.
Kulualp K, Yurdakul I, Erol H, Atalan G, Kilic S. Measurement of intraocular pressure in clinically normal Turkish Shepherd Dogs with the rebound tonometer (TonoVet®) and the applanation tonometer (Tono-Pen Vet®). Med Weter. 2018;74(09):568-573.
Del Sole MJ, Sande PH, Bernades JM, Aba MA, Rosenstein RE. Circadian rhythm of intraocular pressure in cats. Vet Ophthalmol. 2007;10(3):155-161.
Rajaei SM, Asadi F, Rajabian MR, Ostadhassan H, Crasta M. Effect of body position, eyelid manipulation, and manual jugular compression on intraocular pressure in clinically normal cats. Vet Ophthalmol. 2018;21(2):140-143.
Abbott JA. Heart rate and heart rate variability of healthy cats in home and hospital environments. J Feline Med Surg. 2005;7(3):195-202.
Levy JK, Nutt KR, Tucker SJ. Reference interval for rectal temperature in healthy confined adult cats. J Feline Med Surg. 2015;17(11):950-952.
Dijkstra E, Teske E, Szatmari V. Respiratory rate of clinically healthy cats measured in veterinary consultation rooms. Vet J. 2018;234:96-101.
Broadwater JJ, Schorling JJ, Herring IP, Elvinger F. Effect of body position on intraocular pressure in dogs without glaucoma. Am J Vet Res. 2008;69(4):527-530.
von Spiessen L, Karck J, Rohn K, Meyer-Lindenberg A. Clinical comparison of the TonoVet(®) rebound tonometer and the Tono-Pen Vet(®) applanation tonometer in dogs and cats with ocular disease: glaucoma or corneal pathology. Vet Ophthalmol. 2015;18(1):20-27.
Park YW, Jeong MB, Kim TH, et al. Effect of central corneal thickness on intraocular pressure with the rebound tonometer and the applanation tonometer in normal dogs. Vet Ophthalmol. 2011;14(3):169-173.
Grant Information:
The Special Project 2019, Faculty of Veterinary Science, Chulalongkorn University
Contributed Indexing:
Keywords: TONOVET Plus; brachycephalic; cat; intraocular pressure; nonbrachycephalic; tonometry
Entry Date(s):
Date Created: 20210906 Date Completed: 20211108 Latest Revision: 20211108
Update Code:
20240105
DOI:
10.1111/vop.12929
PMID:
34487613
Czasopismo naukowe
Objective: To compare intraocular pressure using the Icare® TONOVET Plus rebound tonometer in healthy brachycephalic and nonbrachycephalic cats.
Animals Studied: Both eyes of 78 healthy cats were investigated in this study. Cats were divided into two groups: brachycephalic (n = 39) and nonbrachycephalic (n = 39).
Procedures: Nose position and muzzle ratio were photographically recorded and analyzed. Physical and ophthalmic examinations were performed. Intraocular pressure was measured using the Icare® TONOVET Plus rebound tonometry instrument. Quantitative mean values were statistically compared using an unpaired t-test at a significance level of p < .05.
Results: Mean values of the nose position and muzzle ratio were significantly lower in the brachycephalic group (20.14 ± 5.43%, 9.61 ± 3.29%) compared with the nonbrachycephalic group (29.21 ± 4.30%, 13.97 ± 6.01%). The mean intraocular pressure for brachycephalic cats (15.76 ± 0.50 mmHg) was significantly lower (p < .001) than for nonbrachycephalic cats (18.77 ± 0.49 mmHg).
Conclusions: Intraocular pressure was significantly lower in brachycephalic cats using the Icare® TONOVET Plus rebound tonometer. Intraocular pressure values obtained in this study could be used as a guideline for measurements obtained using this tonometry device in healthy brachycephalic and nonbrachycephalic cats.
(© 2021 American College of Veterinary Ophthalmologists.)

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies