Proof-of-concept and concurrent validity of a prototype headset to assess peak oxygen uptake without a face mask.

Tytuł:
Proof-of-concept and concurrent validity of a prototype headset to assess peak oxygen uptake without a face mask.
Autorzy:
Düking P; Integrative and Experimental Exercise Science and Training, Department of Sport Science, University of Würzburg, Würzburg, Germany. .
Kunz P; Integrative and Experimental Exercise Science and Training, Department of Sport Science, University of Würzburg, Würzburg, Germany.
Engel FA; Integrative and Experimental Exercise Science and Training, Department of Sport Science, University of Würzburg, Würzburg, Germany.
Mastek H; Integrative and Experimental Exercise Science and Training, Department of Sport Science, University of Würzburg, Würzburg, Germany.
Sperlich B; Integrative and Experimental Exercise Science and Training, Department of Sport Science, University of Würzburg, Würzburg, Germany.
Źródło:
BMC research notes [BMC Res Notes] 2022 Jan 08; Vol. 15 (1), pp. 4. Date of Electronic Publication: 2022 Jan 08.
Typ publikacji:
Journal Article
Język:
English
Imprint Name(s):
Original Publication: London : Biomed Central, 2008.
MeSH Terms:
Masks*
Oxygen Consumption*
Exercise Test ; Humans ; Oxygen ; Reproducibility of Results
References:
J Sports Sci. 2010 May;28(7):733-42. (PMID: 20419553)
Exp Physiol. 2019 Aug;104(8):1215-1225. (PMID: 31116468)
Sports Med. 2000 Jul;30(1):1-15. (PMID: 10907753)
Int J Sports Med. 2005 Feb;26 Suppl 1:S2-10. (PMID: 15702453)
Eur J Appl Physiol. 2020 Dec;120(12):2705-2713. (PMID: 32918588)
Sports Med. 2001;31(12):841-61. (PMID: 11665912)
Int J Sports Med. 2005 Feb;26 Suppl 1:S11-8. (PMID: 15702451)
Sports Med. 2008;38(4):297-316. (PMID: 18348590)
JMIR Mhealth Uhealth. 2018 Apr 30;6(4):e102. (PMID: 29712629)
Sports Med. 1998 Oct;26(4):217-38. (PMID: 9820922)
Sports Med. 2002;32(12):795-808. (PMID: 12238942)
Eur J Appl Physiol. 2012 Jul;112(7):2539-47. (PMID: 22075643)
Int J Sports Med. 2005 Feb;26 Suppl 1:S38-48. (PMID: 15702455)
Sports Med Int Open. 2017 Oct 18;1(6):E206-E211. (PMID: 30539109)
JMIR Mhealth Uhealth. 2020 May 6;8(5):e16716. (PMID: 32374274)
Scand J Med Sci Sports. 2015 Dec;25 Suppl 3:1-72. (PMID: 26606383)
Grant Information:
This study was partially financed by the public funder Bayern Innovative (Bavarian State Ministry of Economics) Nuremberg Vitascale & Bavarian State Ministry of Economics; VitaScale GmbH Vitascale & Bavarian State Ministry of Economics; Nuremberg Vitascale & Bavarian State Ministry of Economics; Germany Vitascale & Bavarian State Ministry of Economics
Contributed Indexing:
Keywords: Data-informed training; Digital Health; Innovation; Wearable; eHealth; mHealth
Substance Nomenclature:
S88TT14065 (Oxygen)
Entry Date(s):
Date Created: 20220109 Date Completed: 20220111 Latest Revision: 20220113
Update Code:
20240104
PubMed Central ID:
PMC8742938
DOI:
10.1186/s13104-021-05850-y
PMID:
34998424
Czasopismo naukowe
Objective: Portable gas exchange instruments allow the assessment of peak oxygen uptake (V̇O 2peak ) but are often bulky, expensive and require wearing a face mask thereby limiting their routine application. A newly developed miniaturized headset (VitaScale, Nuremberg, Germany) may overcome these barriers and allow measuring V̇O 2peak without applying a face mask. Here we aimed (i) to disclose the technical setup of a headset incorporating a gas and volume sensor to measure volume flow and expired oxygen concentration and (ii) to assess the concurrent criterion-validity of the headset to measure V̇O 2peak in 44 individuals exercising on a stationary cycle ergometer in consideration of the test-retest reliability of the criterion measure.
Results: The coefficient of variation (CV%) while measuring V̇O 2peak during incremental cycling with the headset was 6.8%. The CV% for reliability of the criterion measure was 4.0% for V̇O 2peak . Based on the present data, the headset might offer a new technology for V̇O 2peak measurement due to its low-cost and mask-free design.
(© 2021. The Author(s).)
Zaloguj się, aby uzyskać dostęp do pełnego tekstu.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies