Tytuł pozycji:

An Investigation on a Plane-Based Dynamic Calibration Method for the Handheld LiDAR Scanner.

Tytuł:
An Investigation on a Plane-Based Dynamic Calibration Method for the Handheld LiDAR Scanner.
Autorzy:
Chio SH; Department of Land Economics, Chengchi University, No. 64, Sec. 2, ZhiNan Rd., Wenshan District, Taipei City 11605, Taiwan.
Źródło:
Sensors (Basel, Switzerland) [Sensors (Basel)] 2022 Jan 04; Vol. 22 (1). Date of Electronic Publication: 2022 Jan 04.
Typ publikacji:
Journal Article
Język:
English
Imprint Name(s):
Original Publication: Basel, Switzerland : MDPI, c2000-
MeSH Terms:
Calibration*
References:
PLoS One. 2019 Feb 27;14(2):e0211392. (PMID: 30811414)
Contributed Indexing:
Keywords: Velodyne VLP-16; calibration; handheld LiDAR scanner; least-squares adjustment
Entry Date(s):
Date Created: 20220111 Date Completed: 20220112 Latest Revision: 20220114
Update Code:
20240104
PubMed Central ID:
PMC8749791
DOI:
10.3390/s22010369
PMID:
35009909
Czasopismo naukowe
A plane-based dynamic calibration method had been proposed by the previous study for the GeoSLAM ZEB Horizon handheld LiDAR scanner. Only one preliminary test was presented. Therefore, three datasets in a calibration field were collected in this study on different dates and at different times on the same date to investigate the efficiency of the proposed calibration approach and calibration results. The calibration results for these three datasets showed that all average residuals were closer to 0, and all a posterior unit weight standard deviations of the adjustment were also significantly reduced after calibration. Moreover, the RMSE (root mean square error) of the check planes was improved by about an average of 32.61%, 28.44%, and 14.7%, respectively, for the three datasets. The improvement was highly correlated with the quality of the calibration data. The RMSE differences of all check planes using calibration data collected on different dates and at different times on the same date for calibration was about 1-2 cm and less than 1 mm, respectively. There was no difference in the calibration results, demonstrating the efficiency of the proposed calibration approach and the calibration results during the two different dates.
Zaloguj się, aby uzyskać dostęp do pełnego tekstu.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies