Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Low-cost and prototype-friendly method for biocompatible encapsulation of implantable electronics with epoxy overmolding, hermetic feedthroughs and P3HT coating.

Tytuł:
Low-cost and prototype-friendly method for biocompatible encapsulation of implantable electronics with epoxy overmolding, hermetic feedthroughs and P3HT coating.
Autorzy:
Novák M; Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic. .; Department of Medical Biophysics and Medical Informatics, Third Faculty of Medicine, Charles University, Prague, Czech Republic. .
Rosina J; Department of Medical Biophysics and Medical Informatics, Third Faculty of Medicine, Charles University, Prague, Czech Republic.; Department of Health Care and Population Protection, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic.
Bendová H; Centre of Toxicology and Health Safety, National Institute of Public Health, Prague, Czech Republic.
Kejlová K; Centre of Toxicology and Health Safety, National Institute of Public Health, Prague, Czech Republic.
Vlková A; Centre of Toxicology and Health Safety, National Institute of Public Health, Prague, Czech Republic.
Rucki M; Centre of Toxicology and Health Safety, National Institute of Public Health, Prague, Czech Republic.
Svobodová L; Centre of Toxicology and Health Safety, National Institute of Public Health, Prague, Czech Republic.
Gürlich R; Department of General Surgery, Third Faculty of Medicine, Charles University, University Hospital Královské Vinohrady, Prague, Czech Republic.
Hajer J; Department of Internal Medicine, Third Faculty of Medicine, Charles University, University Hospital Královské Vinohrady, Prague, Czech Republic. .
Źródło:
Scientific reports [Sci Rep] 2023 Jan 30; Vol. 13 (1), pp. 1644. Date of Electronic Publication: 2023 Jan 30.
Typ publikacji:
Journal Article; Research Support, Non-U.S. Gov't
Język:
English
Imprint Name(s):
Original Publication: London : Nature Publishing Group, copyright 2011-
MeSH Terms:
Epoxy Resins*
Prostheses and Implants*
Electronics ; Water ; Silicones
References:
J Indian Med Assoc. 2009 Jun;107(6):403-5. (PMID: 19886379)
Biomed Microdevices. 2016 Jun;18(3):42. (PMID: 27165102)
ACM Trans Embed Comput Syst. 2019 Oct;18(5 Suppl):1-22. (PMID: 34084098)
Macromol Biosci. 2010 Apr 8;10(4):378-83. (PMID: 20127671)
Nat Mater. 2015 Jun;14(6):643-51. (PMID: 25985456)
Nat Biomed Eng. 2022 Jun;6(6):706-716. (PMID: 35361934)
Urology. 2017 Apr;102:61-67. (PMID: 27865751)
Sensors (Basel). 2022 Aug 26;22(17):. (PMID: 36080888)
Annu Int Conf IEEE Eng Med Biol Soc. 2015 Aug;2015:809-12. (PMID: 26736385)
J Mater Chem B. 2017 Jan 21;5(3):565-574. (PMID: 32263672)
J Neural Eng. 2012 Feb;9(1):014001. (PMID: 22248468)
Sci Rep. 2021 Mar 1;11(1):4821. (PMID: 33649369)
Adv Healthc Mater. 2020 Sep;9(17):e2000779. (PMID: 32729228)
Regul Toxicol Pharmacol. 2015 Mar;71(2):337-51. (PMID: 25541156)
J Neural Eng. 2021 Sep 21;18(5):. (PMID: 34542029)
Med Biol Eng Comput. 2015 Apr;53(4):319-29. (PMID: 25559120)
Micromachines (Basel). 2021 Aug 27;12(9):. (PMID: 34577664)
Congest Heart Fail. 2010 Jul-Aug;16(4):147-52. (PMID: 20662866)
IEEE Trans Very Large Scale Integr VLSI Syst. 2018 Oct;26(10):2185-2189. (PMID: 30288017)
Micromachines (Basel). 2019 Jul 31;10(8):. (PMID: 31370259)
Substance Nomenclature:
0 (Epoxy Resins)
059QF0KO0R (Water)
0 (Silicones)
Entry Date(s):
Date Created: 20230130 Date Completed: 20230201 Latest Revision: 20230314
Update Code:
20240105
PubMed Central ID:
PMC9887057
DOI:
10.1038/s41598-023-28699-6
PMID:
36717683
Czasopismo naukowe
The research of novel implantable medical devices is one of the most attractive, yet complex areas in the biomedical field. The design and development of sufficiently small devices working in an in vivo environment is challenging but successful encapsulation of such devices is even more so. Industry-standard methods using glass and titanium are too expensive and tedious, and epoxy or silicone encapsulation is prone to water ingress with cable feedthroughs being the most frequent point of failure. This paper describes a universal and straightforward method for reliable encapsulation of circuit boards that achieves ISO10993 compliance. A two-part PVDF mold was machined using a conventional 3-axis machining center. Then, the circuit board with a hermetic feedthrough was placed in the mold and epoxy resin was injected into the mold under pressure to fill the cavity. Finally, the biocompatibility was further enhanced with an inert P3HT polymer coating which can be easily formulated into an ink. The biocompatibility of the encapsulants was assessed according to ISO10993. The endurance of the presented solution compared to silicone potting and epoxy potting was assessed by submersion in phosphate-buffered saline solution at 37 °C. The proposed method showed superior results to PDMS and simple epoxy potting.
(© 2023. The Author(s).)
Zaloguj się, aby uzyskać dostęp do pełnego tekstu.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies