Computed diffusion-weighted MRI for prostate cancer detection: the influence of the combinations of b-values.

Tytuł:
Computed diffusion-weighted MRI for prostate cancer detection: the influence of the combinations of b-values.
Autorzy:
UENO, Y.
TAKAHASHI, S.
OHNO, Y.
KITAJIMA, K.
YUI, M.
KASSAI, Y.
KAWAKAMI, F.
MIYAKE, H.
SUGIMURA, K.
Temat:
DIAGNOSIS
PROSTATE cancer
DIFFUSION magnetic resonance imaging
MAGNETIC resonance imaging
IMAGE quality analysis
RADIOLOGICAL research
Źródło:
British Journal of Radiology; Apr2015, Vol. 88 Issue 1048, p1-8, 8p
Czasopismo naukowe
Objective: To evaluate the influence of the combinations of b-values on computed diffusion-weighted images (cDWIs) for prostate cancer (PCa) detection at b = 2000s mm-2. Methods: Diffusion-weighted imaging (DWIs) for 31 patients with PCa (65.2 ±7.1 years) were obtained pre-operatively at different b-values (0,100, 500,1000 and 2000smm-2) on a 3-T MRI. cDWIs at b = 2000 were generated by using six b-value combinations: 0-100 s mm-2 (cDWI0-100); 0-500 s mm-2 (cDWI0-500); 100-500s mm-2 (cDWI100-500);0-1000s mm2 (cDWI-0-1000); 100-1000smm-2 (cDWI100-500)1 and 500-1000 s mm2 (cDWI500-1000). These cDWIs and measured DWIs with b = 2000 s mm-2 (mDWI2000) were evaluated in this setting. To assess image quality for each DWI, contrast ratios (CRs) of cancerous and non-cancerous lesions were evaluated. To compare the detectability of PCa for each DWI, receiver operating characteristic analysis was used. Results: CRs of all cDWIs were significantly higher than those of mDWI2000 (p<0.05). Areas under the curve of cDWI0-0-100 (0.62) and cDWI0-500 (0.65) were significantly smaller (P < 0.05) than those of others (cDWI100-500 0.72; cDWI0-1000, 0.73; cDWI100-1000. 0.71; cDWI500-1000. 0.74; mDWI2000. 0.72). Conclusion: The combinations of b-values influenced imago quality and diagnostic ability of cDWIs for PCa detection. The combinations of b ≥ 100 and b ≥ 500 s mm-2, as well as b = 0 and b = 1000s mm-2, were optimal in this study. Advances in knowledge: For generating the useful cDWI for PCa detection, radiologists should take care of the combination of b-values when including low b-values. [ABSTRACT FROM AUTHOR]
Copyright of British Journal of Radiology is the property of Oxford University Press / USA and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies