Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Temporary metallic stent placement in the treatment of refractory benign esophageal strictures: results and factors associated with outcome in 55 patients.

Tytuł:
Temporary metallic stent placement in the treatment of refractory benign esophageal strictures: results and factors associated with outcome in 55 patients.
Autorzy:
Kim JH
Song HY
Choi EK
Kim KR
Shin JH
Lim JO
Kim, Jin Hyoung
Song, Ho-Young
Choi, Eugene K
Kim, Kyung Rae
Shin, Ji Hoon
Lim, Jin-Oh
Źródło:
European Radiology; Feb2009, Vol. 19 Issue 2, p384-390, 7p
Czasopismo naukowe
The purpose of this study was to evaluate the effectiveness of temporary metallic stenting in 55 patients with treatment-resistant benign esophageal strictures and to identify factors associated with clinical outcomes. Under fluoroscopic guidance, covered retrievable stents were placed in 55 patients with benign esophageal strictures and were removed with retrieval hook 1 week to 6 months after placement. Stent placement was successful in all patients, and the mean dysphagia score was reduced from 2.8 to 1.3 (p<0.001). The most common complications were tissue hyperproliferation (31%), severe pain (24%), and stent migration (25%). During follow-up (mean: 38 months), recurrence of the stricture necessitating balloon dilation was seen in 38 (69%) of 55 patients. Maintained patency rates after temporary stenting at 1, 3, and 6 months and 1, 2, and 4 years were 58%, 43%, 38%, 33%, 26%, and 21%, respectively. In multivariate analysis, length (p=0.003) of the stricture was the only significant factor associated with maintained patency after temporary stenting. In conclusion, temporary metallic stenting for refractory benign esophageal strictures may be effective during the period of stent placement, but is disadvantaged by the high recurrence rates after stent removal, particularly in patients with a long length of stricture (>7 cm). [ABSTRACT FROM AUTHOR]
Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies