Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Development of –1 MV DC Filter and High‐Voltage DC Measurement Systems for ITER NBI.

Tytuł:
Development of –1 MV DC Filter and High‐Voltage DC Measurement Systems for ITER NBI.
Autorzy:
TAKAHASHI, A. K. E. S. H. I.
TANAKA, T. O. S. H. I. A. K. I.
FUJITA, H. I. R. O. Y. U. K. I.
HIRANUMA, Y. U. K. I.
ICHIMURA, S. A. T. O. S. H. I.
WATANABE, K. A. Z. U. H. I. R. O.
KASHIWAGI, M. I. E. K. O.
MAEJIMA, T. E. T. S. U. Y. A.
Temat:
ELECTRIC circuit design & construction
DIRECT current circuits
FUSION reactors
NUCLEAR fusion
Źródło:
Electrical Engineering in Japan; Aug2018, Vol. 204 Issue 3, p41-52, 12p, 2 Color Photographs, 10 Diagrams, 5 Charts, 3 Graphs
Przedsiębiorstwo/ jednostka:
INTERNATIONAL Thermonuclear Experimental Reactor (Project)
Czasopismo naukowe
SUMMARY: This paper presents the development results of a −1 MV dc filter and dc measurement systems for an ITER (International Thermonuclear Experimental Reactor) neutral beam injector (NBI) system. High accuracy of 0.5% and fast responsivity of 3.3 μs, −3 dB are required for the dc measurement systems: both dc voltage dividers and DCCTs. Circuit design and thermal flow design were carried out to clarify and minimize their effects on the accuracy and responsivity. The validity of the established design was demonstrated by the actual‐product tests; temperature rise of each components fell below the allowable value; inner components of dc filter withstood dc −1.2 MV; each voltage divider accurately measured the voltage during the dc −1.2 MV withstand voltage test; the voltage dividers and the DCCTs were adequate to the requirements of responsivity (3.3 μs, −3 dB). [ABSTRACT FROM AUTHOR]
Copyright of Electrical Engineering in Japan is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies