Experimental investigations on R430A as a drop-in substitute for R134a in domestic refrigerators.

Tytuł:
Experimental investigations on R430A as a drop-in substitute for R134a in domestic refrigerators.
Autorzy:
Mohanraj, M
Źródło:
Proceedings of the Institution of Mechanical Engineers: Part E: Journal of Process Mechanical Engineering (Sage Publications, Ltd.); Aug2019, Vol. 233 Issue 4, p728-738, 11p
Czasopismo naukowe
In this work, the energy performance of a domestic refrigerator has been experimentally investigated using R430A as a possible drop-in substitute to replace R134a. Experiments have been carried out in an R134a-based single evaporator domestic refrigerator of total volume 190 L. The pull-down and ON/OFF cycle performance tests were carried out at 32 ± 0.3 ℃ ambient temperature. The continuous running performance test was carried out for wide range of ambient temperatures between 24 ℃ and 43 ℃ by maintaining evaporator temperature at −12 ± 0.2 ℃. The experimental results showed that the R430A has 3.9% lower energy consumption with 3.8%–6.4% higher coefficient of performance when compared to R134a. However, the compressor discharge temperature of R430A was observed to be 2 ℃–4 ℃ higher when compared to R134a. The lubricant used in R134a compressors is physically stable and retains its lubricant property at 4 ℃ elevated temperature when operating with R430A. The total equivalent warming impact of R430A was found to be 4%–5% lower when compared to R134a due to its higher energy efficiency and lower global warming potential. The results confirmed that R430A is found to be a good drop-in substitute to phase out R134a in domestic refrigerator servicing sectors. [ABSTRACT FROM AUTHOR]
Copyright of Proceedings of the Institution of Mechanical Engineers: Part E: Journal of Process Mechanical Engineering (Sage Publications, Ltd.) is the property of Sage Publications Inc. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies