Fast in vivo 23Na imaging and T2∗ mapping using accelerated 2D‐FID UTE magnetic resonance spectroscopic imaging at 3 T: Proof of concept and reliability study.

Tytuł :
Fast in vivo Na imaging and T2∗ mapping using accelerated 2D‐FID UTE magnetic resonance spectroscopic imaging at 3 T: Proof of concept and reliability study.
Autorzy :
Alhulail, Ahmad A.
Xia, Pingyu
Shen, Xin
Nichols, Miranda
Volety, Srijyotsna
Farley, Nicholas
Thomas, Micheal Albert
Nagel, Armin M.
Dydak, Ulrike
Emir, Uzay E.
Pokaż więcej
Temat :
MAGNETIC resonance imaging
CALF muscles
PROOF of concept
SKELETAL muscle
Źródło :
Magnetic Resonance in Medicine; Apr2021, Vol. 85 Issue 4, p1783-1794, 12p
Czasopismo naukowe
Purpose: To implement an accelerated MR‐acquisition method allowing to map T2∗ relaxation and absolute concentration of sodium within skeletal muscles at 3T. Methods: A fast‐UTE‐2D density‐weighted concentric‐ring‐trajectory 23Na‐MRSI technique was used to acquire 64 time points of FID with a spectral bandwidth of 312.5 Hz with an in‐plane resolution of 2.5 × 2.5 mm2 in ~15 min. The fast‐relaxing 23Na signal was localized with a single‐shot, inversion‐recovery‐based, non‐echo (SIRENE) outer volume suppression (OVS) method. The sequence was verified using simulation and phantom studies before implementing it in human calf muscles. To evaluate the 2D‐SIRENE‐MRSI (UTE = 0.55 ms) imaging performance, it was compared to a 3D‐MRI (UTE = 0.3 ms) sequence. Both data sets were acquired within 2 same‐day sessions to assess repeatability. The T2∗ values were fitted voxel‐by‐voxel using a biexponential model for the 2D‐MRSI data. Finally, intra‐subject coefficients of variation (CV) were estimated. Results: The MRSI‐FID data allowed us to map the fast and slow components of T2∗ in the calf muscles. The spatial distributions of 23Na concentration for both MRSI and 3D‐MRI acquisitions were significantly correlated (P <.001). The test–retest analysis rendered high repeatability for MRSI with a CV of 5%. The mean T2Fast∗ in muscles was 0.7 ± 0.1 ms (contribution fraction = 37%), whereas T2Slow∗ was 13.2 ± 0.2 ms (63%). The mean absolute muscle 23Na concentration calculated from the T2∗‐corrected data was 28.6 ± 3.3 mM. Conclusion: The proposed MRSI technique is a reliable technique to map sodium's absolute concentration and T2∗ within a clinically acceptable scan time at 3T. [ABSTRACT FROM AUTHOR]
Copyright of Magnetic Resonance in Medicine is the property of John Wiley & Sons, Inc. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies