Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Factors related to passing the safety fast test among neonates with hypoglycaemia in the neonatal intensive care unit.

Tytuł:
Factors related to passing the safety fast test among neonates with hypoglycaemia in the neonatal intensive care unit.
Autorzy:
Olowoyeye, Abiola
Eisenberg, Ruth
Kim, Mimi
Havranek, Tomas
Temat:
INTENSIVE care units
NEONATAL intensive care
NEWBORN infants
GLUCOSE clamp technique
BLOOD sugar
INTRAVENOUS therapy
Źródło:
Journal of Paediatrics & Child Health; Apr2021, Vol. 57 Issue 4, p507-512, 6p
Czasopismo naukowe
Aim: To investigate the success rates and predictors of safety fast test among neonates admitted to the neonatal intensive care unit for hypoglycaemia.Methods: A retrospective review of neonates transferred from the newborn nursery unit to the neonatal intensive care unit for intravenous dextrose therapy for hypoglycaemia from January 2016 to June 2019. Neonatal clinical and demographic variables were abstracted from the medical records. A successful safety fast test was defined by blood glucose >60 mg/dL (3.3 mmol/L) at 3, 4, 5 and 6 h after a feed.Results: Of the 76 neonates who had a safety fast test, 80% passed on their first attempt. Neonates who passed the safety fast test were less likely to be premature/small for gestational age (54.1% vs. 92.9%, P = 0.03), required less maximum glucose infusion rate (median 6 vs. 7 mg/kg/min; P = 0.04), and were younger at fasting challenge (median 5 vs. 9 days; P = 0.02), required lower overall intravenous glucose load (median 12 vs. 24 g/kg; P = 0.006).Conclusion: Safety fast test may be a useful tool evaluating discharge readiness of neonates with persistent hypoglycaemia. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Paediatrics & Child Health is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies