Quantification of Myocardial Creatine and Triglyceride Content in the Human Heart: Precision and Accuracy of in vivo Proton Magnetic Resonance Spectroscopy.

Tytuł:
Quantification of Myocardial Creatine and Triglyceride Content in the Human Heart: Precision and Accuracy of in vivo Proton Magnetic Resonance Spectroscopy.
Autorzy:
Bakermans, Adrianus J.
Boekholdt, S. Matthijs
Vries, Dylan K.
Reckman, Yolan J.
Farag, Emile S.
Heer, Paul
Uthman, Laween
Denis, Simone W.
Zuurbier, Coert J.
Houtkooper, Riekelt H.
Koolbergen, David R.
Kluin, Jolanda
Planken, R. Nils
Lamb, Hildo J.
Webb, Andrew G.
Strijkers, Gustav J.
Beard, Daniel A.
Jeneson, Jeroen A.L.
Nederveen, Aart J.
Temat:
PROTON magnetic resonance spectroscopy
CREATINE
TRIGLYCERIDES
AORTIC valve transplantation
Źródło:
Journal of Magnetic Resonance Imaging; Aug2021, Vol. 54 Issue 2, p411-420, 10p
Czasopismo naukowe
Background: Proton magnetic resonance spectroscopy (1H‐MRS) of the human heart is deemed to be a quantitative method to investigate myocardial metabolite content, but thorough validations of in vivo measurements against invasive techniques are lacking. Purpose: To determine measurement precision and accuracy for quantifications of myocardial total creatine and triglyceride content with localized 1H‐MRS. Study type: Test–retest repeatability and measurement validation study. Subjects: Sixteen volunteers and 22 patients scheduled for open‐heart aortic valve replacement or septal myectomy. Field Strength/Sequence: Prospectively ECG‐triggered respiratory‐gated free‐breathing single‐voxel point‐resolved spectroscopy (PRESS) sequence at 3 T. Assessment: Myocardial total creatine and triglyceride content were quantified relative to the total water content by fitting the 1H‐MR spectra. Precision was assessed with measurement repeatability. Accuracy was assessed by validating in vivo 1H‐MRS measurements against biochemical assays in myocardial tissue from the same subjects. Statistical Tests: Intrasession and intersession repeatability was assessed using Bland–Altman analyses. Agreement between 1H‐MRS measurements and biochemical assay was tested with regression analyses. Results: The intersession repeatability coefficient for myocardial total creatine content was 41.8% with a mean value of 0.083% ± 0.020% of the total water signal, and 36.7% for myocardial triglyceride content with a mean value of 0.35% ± 0.13% of the total water signal. Ex vivo myocardial total creatine concentrations in tissue samples correlated with the in vivo myocardial total creatine content measured with 1H‐MRS: n = 22, r = 0.44; P < 0.05. Likewise, ex vivo myocardial triglyceride concentrations correlated with the in vivo myocardial triglyceride content: n = 20, r = 0.50; P < 0.05. Data Conclusion: We validated the use of localized 1H‐MRS of the human heart at 3 T for quantitative assessments of in vivo myocardial tissue metabolite content by estimating the measurement precision and accuracy. Level of Evidence: 2 Technical Efficacy Stage: 2 [ABSTRACT FROM AUTHOR]
Copyright of Journal of Magnetic Resonance Imaging is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies