In addition to its beneficial effect on patient survival, the implanted cardioverter defibrillator (ICD) changes a patient's life physically, socially, and psychologically. For improved patient management, it is important to understand the quality-of-life changes that accompany this mode of treatment. To this end, 119 patients were surveyed retrospectively and interviewed concurrently regarding their emotional, physical, and behavioral responses to ICD shocks and to the device itself Most (55%) correctly estimated the total number of shocks they had received within a 10% margin. They found the shocks severe, 79% assigning a score between 3 and 5 on a scale of 1-5. Common descriptions of the shock sensation were a blow to the body or a spasm causing the entire body to jump. Most patients tolerated the shocks as lifesaving, but 23% dreaded shocks and 5% even said they would rather he without the ICD and take their chances. After a shock, 50% of patients called their physician and 42% continued their daily routine. Thirty percent went to a hospital emergency room or called a rescue service. Sixty-five percent had no preshock prodromes. Fifty-four percent were interested in the programmable option of a warning signal prior to a shock, while 31 % preferred no warning. Of the 74% who were advised not to drive after implantation, 29% drove anyway. Five patients were shocked while driving with no resulting accidents. We conclude that most patients find ICD shocks moderately uncomfortable, but they tolerate them because of the lifesaving protection provided by the device. [ABSTRACT FROM AUTHOR]
Copyright of Pacing & Clinical Electrophysiology is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies