Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Relevance of the skewness index in DTI exploration of multiple sclerosis.

Tytuł:
Relevance of the skewness index in DTI exploration of multiple sclerosis.
Autorzy:
Eliane Graulières
Jean-Albert Lotterie
Emmanuelle Cassol
Angélique Gerdelat
Michel Clanet
Isabelle Berry
Temat:
DIFFUSION tensor imaging
MULTIPLE sclerosis diagnosis
AUTOIMMUNE diseases
BIOMARKERS
PARAMETER estimation
PATIENTS
Źródło:
MAGMA: Magnetic Resonance Materials in Physics, Biology & Medicine; Apr2009, Vol. 22 Issue 2, p89-100, 12p
Czasopismo naukowe
Abstract Object  To this day, no parameter can really monitor the progression of multiple sclerosis (MS). In this study, an index the skewness (S) derived from parameters calculated in diffusion tensor imaging (DTI) has been tested on MS patients for its ability to monitor the disease course. Materials and methods  Eighteen patients underwent two examinations within 3 months consisting of a clinical evaluation (EDSS) and DTI acquisitions on a 1.5 T imager. Tensor was calculated thanks to“home-made” software. Mean diffusivity (MD) and fractional anisotropy (FA) histograms were described for normal-appearing white matter (NAWM) and gray matter (GM) of patients with S and also with usually indices peak position (pp) and peak height (ph) for the whole group of patients and for two separate groups according to their clinical status (EDSS  ≤  3 and EDSS  > 3 at month 0). Results  Although no significant clinical evolution is observed over 3 months, S in GM showed a significant shift for both MD/FA histograms towards abnormal values for the whole group of patients (p = 0.02/p = 0.04) and for the group with EDSS  ≤  3 (p = 0.04/p = 0.007), while ph and pp do not. Conclusion  S in GM could be an alternative marker to monitor the disease course before the repercussion on the clinical score. [ABSTRACT FROM AUTHOR]
Copyright of MAGMA: Magnetic Resonance Materials in Physics, Biology & Medicine is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies