Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

An evaluation of the N-CAT, a new arterial tonometer.

Tytuł:
An evaluation of the N-CAT, a new arterial tonometer.
Autorzy:
Searle, Norman
Gauthier, Jean
Sahab, Philippe
Searle, N R
Gauthier, J
Sahab, P
Temat:
ARTERIAL physiology
BLOOD pressure measurement
CARDIOPULMONARY bypass
EQUIPMENT & supplies
Źródło:
Canadian Journal of Anaesthesia / Journal Canadien d'Anesthésie; 1995, Vol. 42 Issue 6, p526-531, 6p
Abstract (English):
The N-CAT is a newly developed arterial tonometer (TBP) monitor able to determine systolic, diastolic and mean blood pressures continuously and noninvasively. The aim of this study was to evaluate the accuracy and reliability of the TBP compared with directly measured invasive blood pressure (IBP) in 14 patients before and after elective coronary artery bypass surgery. Although the TBP was able to track changes in systemic pressure, before and after CPB, bias and precision for TBP monitoring did not meet the standard criteria for equivalency for noninvasive blood pressure to invasive blood pressure. We were unable to monitor TBP in two patients. Approximately 40% of all before and after CPB mean TBP pressure values differed from mean IBP by more than 10 mmHg. Moreover, there were discrepancies of sufficient magnitude and duration that limits the clinical usefulness of the N-CAT. Potential users should not rely exclusively on TBP values when making clinical decisions. Technological improvement is needed before its clinical use is recommended. [ABSTRACT FROM AUTHOR]
Czasopismo naukowe
Copyright of Canadian Journal of Anaesthesia / Journal Canadien d'Anesthésie is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies