Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Crossover Chimney Technique to Preserve the Internal Iliac Artery in Abdominal Aortic Aneurysm With Common Iliac Artery Aneurysms.

Tytuł:
Crossover Chimney Technique to Preserve the Internal Iliac Artery in Abdominal Aortic Aneurysm With Common Iliac Artery Aneurysms.
Autorzy:
I-Hui Wu
Chih-Yang Chan
Yih-Sharng Chen
Shu-Chien Huang
Shoei-Shen Wang
Nai-Hsin Chi
Źródło:
Journal of Endovascular Therapy; Jun2013, Vol. 20 Issue 3, p298-302, 5p
Czasopismo naukowe
Purpose: To report a new technique to preserve the internal iliac artery (IIA) in cases of aortoiliac aneurysms. Technique: Under bilateral common femoral artery (CFA) exposure, a crossover sheath was inserted from the contralateral CFA to the ipsilateral IIA involved in the common lilac artery (CIA) aneurysm. A Viabahn stent-graft was positioned 2 cm inside the IIA. The main body abdominal stent-graft was inserted through the ipsilateral CFA with distal sealing in the external iliac artery (EIA). The gate was cannulated, and the limb extension was positioned in the contralateral CIA near the IIA orifice. After the first Viabahn deployment, a second device was deployed with a minimum 1-cm overlap inside the first Viabahn and 2 mm distal to the limb extension. For bilateral CIA aneurysms, the Viabahn and extension limb were landed in the EIA with IIA embolization. In the past year, this technique has been used in 5 patients with success. There was no acute branch occlusion or type I endoleak from the IIA or chimney graft gutters on imaging studies up to 6 months. Conclusion: This technique is easy to use and avoids the brachial access of the sandwich technique and the additional cost of an iliac branch device. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Endovascular Therapy is the property of Sage Publications Inc. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies