Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Przeglądasz jako GOŚĆ
Tytuł pozycji:

Assessment of Environmental Contamination and Environmental Decontamination Practices within an Ebola Holding Unit, Freetown, Sierra Leone.

Tytuł :
Assessment of Environmental Contamination and Environmental Decontamination Practices within an Ebola Holding Unit, Freetown, Sierra Leone.
Autorzy :
Youkee, Daniel
Brown, Colin S.
Lilburn, Paul
Shetty, Nandini
Brooks, Tim
Simpson, Andrew
Bentley, Neil
Lado, Marta
Kamara, Thaim B.
Walker, Naomi F.
Johnson, Oliver
Pokaż więcej
Temat :
viruses
Research Article
Science
virus diseases
Medicine
Źródło :
PLoS ONE, Vol 10, Iss 12, p e0145167 (2015)
Wydawca :
Public Library of Science (PLoS), 2015.
Rok publikacji :
2015
Kolekcja :
DOAJ-Articles_enriched
DOAJ-Articles
Oryginalny identyfikator :
pmc: PMC4687095
pmid: 26692018
Język :
English
ISSN :
1932-6203
DOI :
10.1371/journal.pone.0145167
Evidence to inform decontamination practices at Ebola holding units (EHUs) and treatment centres is lacking. We conducted an audit of decontamination procedures inside Connaught Hospital EHU in Freetown, Sierra Leone, by assessing environmental swab specimens for evidence of contamination with Ebola virus by RT-PCR. Swabs were collected following discharge of Ebola Virus Disease (EVD) patients before and after routine decontamination. Prior to decontamination, Ebola virus RNA was detected within a limited area at all bedside sites tested, but not at any sites distant to the bedside. Following decontamination, few areas contained detectable Ebola virus RNA. In areas beneath the bed there was evidence of transfer of Ebola virus material during cleaning. Retraining of cleaning staff reduced evidence of environmental contamination after decontamination. Current decontamination procedures appear to be effective in eradicating persistence of viral RNA. This study supports the use of viral swabs to assess Ebola viral contamination within the clinical setting. We recommend that regular refresher training of cleaning staff and audit of environmental contamination become standard practice at all Ebola care facilities during EVD outbreaks.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies