The mechanical property and corrosion resistance of Mg-Zn-Nd alloy fine wires in vitro and in vivo

Tytuł:
The mechanical property and corrosion resistance of Mg-Zn-Nd alloy fine wires in vitro and in vivo
Autorzy:
Ming Gao
Di Na
Xiangqiao Ni
Lihui Song
Iniobong P. Etim
Ke Yang
Lili Tan
Zheng Ma
Temat:
Magnesium
Surgical staple
Anastomosis
Corrosion resistance
In vivo
Materials of engineering and construction. Mechanics of materials
TA401-492
Biology (General)
QH301-705.5
Źródło:
Bioactive Materials, Vol 6, Iss 1, Pp 55-63 (2021)
Wydawca:
KeAi Communications Co., Ltd., 2021.
Rok publikacji:
2021
Kolekcja:
LCC:Materials of engineering and construction. Mechanics of materials
LCC:Biology (General)
Typ dokumentu:
article
Opis pliku:
electronic resource
Język:
English
ISSN:
2452-199X
Relacje:
http://www.sciencedirect.com/science/article/pii/S2452199X20301389; https://doaj.org/toc/2452-199X
DOI:
10.1016/j.bioactmat.2020.07.011
Dostęp URL:
https://doaj.org/article/1a69f77ea7f84a928598b1bfc2cbec4c  Link otwiera się w nowym oknie
Numer akcesji:
edsdoj.1a69f77ea7f84a928598b1bfc2cbec4c
Czasopismo naukowe
Titanium and its alloy are commonly used as surgical staples in the reconstruction of intestinal tract and stomach, however they cannot be absorbed in human body, which may cause a series of complications to influence further diagnosis. Magnesium and its alloy have great potential as surgical staples, because they can be degraded in human body and have good mechanical properties and biocompatibility. In this study, Mg-2Zn-0.5Nd (ZN20) alloy fine wires showed great potential as surgical staples. The ultimate tensile strength and elongation of ZN20 alloy fine wires were 248 MPa and 13%, respectively, which could be benefit for the deformation of the surgical staples from U-shape to B-shape. The bursting pressure of the wire was about 40 kPa, implying that it can supply sufficient mechanical support after anastomosis. Biochemical test and histological analysis illustrated good biocompatibility and biological safety of ZN20 alloy fine wire. The residual tensile stress formed on the outside of ZN20 fine wire during drawing would accelerate the corrosion. The second phase had a negative influence on corrosion property due to galvanic corrosion. The corrosion rate in vitro was faster than that in vivo due to the capsule formed on the surface of ZN20 alloy fine wire.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies