Multi-Center Repeatability of Macular Capillary Perfusion Density Using Optical Coherence Tomography Angiography

Tytuł:
Multi-Center Repeatability of Macular Capillary Perfusion Density Using Optical Coherence Tomography Angiography
Autorzy:
Jiang H
Simms AG
Sadaghiani S
Jiang YY
Morgan JIW
Aguirre GK
Pattany PM
Detre JA
Wang J
Temat:
retinal capillary perfusion density
optical coherence tomography angiography
repeatability
multi-center study.
Ophthalmology
RE1-994
Źródło:
Clinical Ophthalmology, Vol Volume 16, Pp 3069-3078 (2022)
Wydawca:
Dove Medical Press, 2022.
Rok publikacji:
2022
Kolekcja:
LCC:Ophthalmology
Typ dokumentu:
article
Opis pliku:
electronic resource
Język:
English
ISSN:
1177-5483
Relacje:
https://www.dovepress.com/multi-center-repeatability-of-macular-capillary-perfusion-density-usin-peer-reviewed-fulltext-article-OPTH; https://doaj.org/toc/1177-5483
Dostęp URL:
https://doaj.org/article/1c7e5c4729784bb0a8e3aaa706ffa649  Link otwiera się w nowym oknie
Numer akcesji:
edsdoj.1c7e5c4729784bb0a8e3aaa706ffa649
Czasopismo naukowe
Hong Jiang,1,2 Ava-Gaye Simms,1 Shokufeh Sadaghiani,3 Yu You Jiang,4 Jessica IW Morgan,4 Geoffrey K Aguirre,3 Pradip M Pattany,5 John A Detre,2 Jianhua Wang1 1Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA; 2Department of Neurology, University of Miami Miller School of Medicine, Miami, FL, USA; 3Department of Neurology, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA, USA; 4Scheie Eye Institute and Center for Advanced Retinal and Ocular Therapeutics, Department of Ophthalmology, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA, USA; 5Department of Radiology, University of Miami Miller School of Medicine, Miami, FL, USACorrespondence: Jianhua Wang, Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, 1638 NW 10th Avenue, McKnight Building - Room 202A, Miami, FL, 33136, USA, Tel +1 305 482-5010, Fax +1 305 482-5012, Email jwang3@med.miami.eduBackground/Aims: This study was to determine the test–retest repeatability in quantifying macular capillary perfusion density (CPD, expressed as fractal dimension) using optical coherence tomography angiography (OCTA) in a multi-center setting.Methods: OCTA data were obtained in self-reported healthy subjects from Bascom Palmer Eye Institute at the University of Miami (UM, N = 18) and the University of Pennsylvania (UPenn, N = 22). The right eye of each subject was imaged twice at the first visit and then again at an interval of one week to assess intra-visit and inter-visit repeatability. The macular area of the OCTA-derived capillary perfusion density (OCTA-CPD) was analyzed by custom-made image processing and fractal analysis software. Fractal analysis was performed on the skeletonized microvascular network to yield OCTA-CPD by box-counting to the fractal dimension (Dbox) in the superficial vascular plexus (SVP). Repeatability was assessed by three measures: within-subject standard deviation (Sw), coefficient of variation (CoV) of repeated measures, and intraclass correlation coefficient (ICC).Results: OCTA-CPD from both sites (UM and UPENN) showed good to excellent intra-visit repeatability, as demonstrated by the Sw ≤ 0.004, CoVs ≤ 0.23%, and ICCs ≥ 0.61. Similarly, both sites had good to excellent inter-visit repeatability, as shown by the Sw ≤ 0.005, CoVs ≤ 0.28%, and ICCs ≥ 0.61. The Bland-Altman plots of the intra-visit and inter-visit measurements showed excellent agreements between the paired measurements with minimal biases.Conclusion: Our data showed that comparable high repeatability of OCTA-CPD can be achieved in both research sites using the same device, scan protocol, and image analysis.Keywords: retinal capillary perfusion density, optical coherence tomography angiography, repeatability, multi-center study
Zaloguj się, aby uzyskać dostęp do pełnego tekstu.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies