Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

In vitro optimization and comparison of CT angiography versus radial cardiovascular magnetic resonance for the quantification of cross-sectional areas and coronary endothelial function

Tytuł:
In vitro optimization and comparison of CT angiography versus radial cardiovascular magnetic resonance for the quantification of cross-sectional areas and coronary endothelial function
Autorzy:
Jérôme Yerly
Fabio Becce
Ruud B. van Heeswijk
Francis R. Verdun
Danilo Gubian
Reto Meuli
Matthias Stuber
Temat:
Accuracy
CT angiography
Coronary artery
Cross-sectional area
Endothelial function
Limit of detection
Diseases of the circulatory (Cardiovascular) system
RC666-701
Źródło:
Journal of Cardiovascular Magnetic Resonance, Vol 21, Iss 1, Pp 1-17 (2019)
Wydawca:
Elsevier, 2019.
Rok publikacji:
2019
Kolekcja:
LCC:Diseases of the circulatory (Cardiovascular) system
Typ dokumentu:
article
Opis pliku:
electronic resource
Język:
English
ISSN:
1532-429X
Relacje:
http://link.springer.com/article/10.1186/s12968-019-0521-z; https://doaj.org/toc/1532-429X
DOI:
10.1186/s12968-019-0521-z
Dostęp URL:
https://doaj.org/article/2fe36cc2e35c48b49fcd28f655ce3550  Link otwiera się w nowym oknie
Numer akcesji:
edsdoj.2fe36cc2e35c48b49fcd28f655ce3550
Czasopismo naukowe
Abstract Background Our objectives were first to determine the optimal coronary computed tomography angiography (CTA) protocol for the quantification and detection of simulated coronary artery cross-sectional area (CSA) differences in vitro, and secondly to quantitatively compare the performance of the optimized CTA protocol with a previously validated radial coronary cardiovascular magnetic resonance (CMR) technique. Methods 256-multidetector CTA and radial coronary CMR were used to obtain images of a custom in vitro resolution phantom simulating a range of physiological responses of coronary arteries to stress. CSAs were automatically quantified and compared with known nominal values to determine the accuracy, precision, signal-to-noise ratio (SNR), and circularity of CSA measurements, as well as the limit of detection (LOD) of CSA differences. Various iodine concentrations, radiation dose levels, tube potentials, and iterative image reconstruction algorithms (ASiR-V) were investigated to determine the optimal CTA protocol. The performance of the optimized CTA protocol was then compared with a radial coronary CMR method previously developed for endothelial function assessment under both static and moving conditions. Results The iodine concentration, dose level, tube potential, and reconstruction algorithm all had significant effects (all p
Zaloguj się, aby uzyskać dostęp do pełnego tekstu.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies