Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

A new CFD based non-invasive method for functional diagnosis of coronary stenosis

Tytuł:
A new CFD based non-invasive method for functional diagnosis of coronary stenosis
Autorzy:
Xinzhou Xie
Minwen Zheng
Didi Wen
Yabing Li
Songyun Xie
Temat:
Functional coronary stenosis
Non-invasive assessment
Pressure-flow curve
CFD
Medical technology
R855-855.5
Źródło:
BioMedical Engineering OnLine, Vol 17, Iss 1, Pp 1-13 (2018)
Wydawca:
BMC, 2018.
Rok publikacji:
2018
Kolekcja:
LCC:Medical technology
Typ dokumentu:
article
Opis pliku:
electronic resource
Język:
English
ISSN:
1475-925X
Relacje:
http://link.springer.com/article/10.1186/s12938-018-0468-6; https://doaj.org/toc/1475-925X
DOI:
10.1186/s12938-018-0468-6
Dostęp URL:
https://doaj.org/article/3227487ed66340f895cae7639986161a  Link otwiera się w nowym oknie
Numer akcesji:
edsdoj.3227487ed66340f895cae7639986161a
Czasopismo naukowe
Abstract Background Accurate functional diagnosis of coronary stenosis is vital for decision making in coronary revascularization. With recent advances in computational fluid dynamics (CFD), fractional flow reserve (FFR) can be derived non-invasively from coronary computed tomography angiography images (FFRCT) for functional measurement of stenosis. However, the accuracy of FFRCT is limited due to the approximate modeling approach of maximal hyperemia conditions. To overcome this problem, a new CFD based non-invasive method is proposed. Methods Instead of modeling maximal hyperemia condition, a series of boundary conditions are specified and those simulated results are combined to provide a pressure-flow curve for a stenosis. Then, functional diagnosis of stenosis is assessed based on parameters derived from the obtained pressure-flow curve. Results The proposed method is applied to both idealized and patient-specific models, and validated with invasive FFR in six patients. Results show that additional hemodynamic information about the flow resistances of a stenosis is provided, which cannot be directly obtained from anatomy information. Parameters derived from the simulated pressure-flow curve show a linear and significant correlations with invasive FFR (r > 0.95, P < 0.05). Conclusion The proposed method can assess flow resistances by the pressure-flow curve derived parameters without modeling of maximal hyperemia condition, which is a new promising approach for non-invasive functional assessment of coronary stenosis.
Zaloguj się, aby uzyskać dostęp do pełnego tekstu.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies