Tytuł pozycji:

Effects on Load-Frequency Control of a Solar Power System with a Two-Area Interconnected Thermal Power Plant and its Control with a New BFA Algorithm

Tytuł:
Effects on Load-Frequency Control of a Solar Power System with a Two-Area Interconnected Thermal Power Plant and its Control with a New BFA Algorithm
Autorzy:
Zafer Civelek
Goksu Gorel
Murat Luy
Necaattin Barısci
Ertugrul Cam
Temat:
automatic generation control
fuzzy control
optimization
power system stability.
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
Źródło:
Elektronika ir Elektrotechnika, Vol 24, Iss 6, Pp 3-10 (2018)
Wydawca:
Kaunas University of Technology, 2018.
Rok publikacji:
2018
Kolekcja:
LCC:Electrical engineering. Electronics. Nuclear engineering
Typ dokumentu:
article
Opis pliku:
electronic resource
Język:
English
ISSN:
1392-1215
2029-5731
Relacje:
http://eejournal.ktu.lt/index.php/elt/article/view/22281; https://doaj.org/toc/1392-1215; https://doaj.org/toc/2029-5731
DOI:
10.5755/j01.eie.24.6.22281
Dostęp URL:
https://doaj.org/article/3799243e7b4547b78077f0c02f2e94d8  Link otwiera się w nowym oknie
Numer akcesji:
edsdoj.3799243e7b4547b78077f0c02f2e94d8
Czasopismo naukowe
A control operation is the most important part of stabilization between load and frequency in a power system. The demand power change and the generated power change can disrupt the load-frequency balance. For this reason, the system frequency value should be controlled by some methods. In this study, a load frequency control was performed in a two-area power system. The renewable solar energy system and the interconnected power system were connected. In order to control the load-frequency balance, the classical PI, PID, Fuzzy Logic Controller (FLC) based PI and Bacterial Foraging Algorithm (BFA) based PI controller were separately designed and implemented to control the frequency value. All the trials were simulated and confirmed by the MATLAB/Simulink program. According to the results obtained from the control methods, the BFA-PI method provided better overshoots and BFA-PI had better settling times than the others. DOI: http://dx.doi.org/10.5755/j01.eie.24.6.22281

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies