Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Occurrence of pendelluft under pressure support ventilation in patients who failed a spontaneous breathing trial: an observational study

Tytuł:
Occurrence of pendelluft under pressure support ventilation in patients who failed a spontaneous breathing trial: an observational study
Autorzy:
Andrea Coppadoro
Alice Grassi
Cecilia Giovannoni
Francesca Rabboni
Nilde Eronia
Alfio Bronco
Giuseppe Foti
Roberto Fumagalli
Giacomo Bellani
Temat:
Pendelluft
Electrical impedance tomography
Difficult ventilator weaning
Assisted mechanical ventilation
Spontaneous assisted breathing
Spontaneous breathing trial
Medical emergencies. Critical care. Intensive care. First aid
RC86-88.9
Źródło:
Annals of Intensive Care, Vol 10, Iss 1, Pp 1-10 (2020)
Wydawca:
SpringerOpen, 2020.
Rok publikacji:
2020
Kolekcja:
LCC:Medical emergencies. Critical care. Intensive care. First aid
Typ dokumentu:
article
Opis pliku:
electronic resource
Język:
English
ISSN:
2110-5820
Relacje:
http://link.springer.com/article/10.1186/s13613-020-00654-y; https://doaj.org/toc/2110-5820
DOI:
10.1186/s13613-020-00654-y
Dostęp URL:
https://doaj.org/article/436ed4a53d5342d7b2cc6e781d8c2d9d  Link otwiera się w nowym oknie
Numer akcesji:
edsdoj.436ed4a53d5342d7b2cc6e781d8c2d9d
Czasopismo naukowe
Abstract Background Pendelluft, the movement of gas within different lung regions, is present in animal models of assisted mechanical ventilation and associated with lung overstretching. Due to rebreathing of CO2 as compared to fresh gas, pendelluft might reduce ventilatory efficiency possibly exacerbating patient’s respiratory workload during weaning. Our aim was to measure pendelluft by electrical impedance tomography (EIT) in patients who failed a spontaneous breathing trial (SBT). Methods This is an observational study conducted in a general intensive care unit of a tertiary-level teaching hospital. EIT signal was recorded in 20 patients while pressure support (PS) ventilation was progressively reduced from clinical level (baseline) to 2 cmH2O, as in an SBT; four ventral-to-dorsal lung regions of interest were identified for pendelluft measurement. A regional gas movement (> 6 mL) occurring in a direction opposite to the global EIT signal was considered diagnostic for high pendelluft. Results Eight patients out of 20 (40%) were classified as high-pendelluft; baseline clinical characteristics did not differ between high- and low-pendelluft patients. At PS reduction, pendelluft and EtCO2 increased more in the high-pendelluft group (p
Zaloguj się, aby uzyskać dostęp do pełnego tekstu.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies