Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Application of the Enzymatic Electrochemical Biosensors for Monitoring Non-Competitive Inhibition of Enzyme Activity by Heavy Metals

Tytuł:
Application of the Enzymatic Electrochemical Biosensors for Monitoring Non-Competitive Inhibition of Enzyme Activity by Heavy Metals
Autorzy:
Amir M. Ashrafi
Milan Sýs
Eliška Sedláčková
Amir Shaaban Farag
Vojtěch Adam
Jan Přibyl
Lukáš Richtera
Temat:
glucose oxidase
heavy metals
amperometric biosensor
non-competitive inhibition
Chemical technology
TP1-1185
Źródło:
Sensors, Vol 19, Iss 13, p 2939 (2019)
Wydawca:
MDPI AG, 2019.
Rok publikacji:
2019
Kolekcja:
LCC:Chemical technology
Typ dokumentu:
article
Opis pliku:
electronic resource
Język:
English
ISSN:
1424-8220
Relacje:
https://www.mdpi.com/1424-8220/19/13/2939; https://doaj.org/toc/1424-8220
DOI:
10.3390/s19132939
Dostęp URL:
https://doaj.org/article/4b2991049cc24753b5180f3d597b0981  Link otwiera się w nowym oknie
Numer akcesji:
edsdoj.4b2991049cc24753b5180f3d597b0981
Czasopismo naukowe
The inhibition effect of the selected heavy metals (Ag+, Cd2+, Cu2+, and Hg2+) on glucose oxidase (GOx) enzyme from Aspergillus niger (EC 1.1.3.4.) was studied using a new amperometric biosensor with an electrochemical transducer based on a glassy carbon electrode (GCE) covered with a thin layer of multi-wall carbon nanotubes (MWCNTs) incorporated with ruthenium(IV) oxide as a redox mediator. Direct adsorption of multi-wall carbon nanotubes (MWCNTs) and subsequent covering with Nafion® layer was used for immobilization of Gox. The analytical figures of merit of the developed glucose (Glc) biosensor are sufficient for determination of Glc in body fluids in clinical analysis. From all tested heavy metals, mercury(II) has the highest inhibition effect. However, it is necessary to remember that cadmium and silver ions also significantly inhibit the catalytic activity of Gox. Therefore, the development of Gox biosensors for selective indirect determination of each heavy metal still represents a challenge in the field of bioelectroanalysis. It can be concluded that amperometric biosensors, differing in the utilized enzyme, could find their application in the toxicity studies of various poisons.
Zaloguj się, aby uzyskać dostęp do pełnego tekstu.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies