Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Plastic versus glass capillaries for rapid-cycle PCR

Tytuł:
Plastic versus glass capillaries for rapid-cycle PCR
Autorzy:
Oluwole Elenitoba-Johnson
Derek David
Niel Crews
Carl T. Wittwer
Temat:
Biology (General)
QH301-705.5
Źródło:
BioTechniques, Vol 44, Iss 4, Pp 487-492 (2008)
Wydawca:
Future Science Ltd, 2008.
Rok publikacji:
2008
Kolekcja:
LCC:Biology (General)
Typ dokumentu:
article
Opis pliku:
electronic resource
Język:
English
ISSN:
1940-9818
0736-6205
Relacje:
https://doaj.org/toc/0736-6205; https://doaj.org/toc/1940-9818
DOI:
10.2144/000112722
Dostęp URL:
https://doaj.org/article/4eb2f967346a43998d90b547a09771e9  Link otwiera się w nowym oknie
Numer akcesji:
edsdoj.4eb2f967346a43998d90b547a09771e9
Czasopismo naukowe
Rapid-cycle PCR uses fast temperature transitions and minimal denaturation and annealing times of “0” s to complete 30 cycles in 10 to 30 min. The most popular platform amplifies samples in glass capillaries arranged around a carousel with circulating air for temperature control. Recently, plastic capillary replacements for glass capillaries became available. We compared the performance of plastic and glass capillaries for rapid-cycle PCR. Heat transfer into plastic capillaries was slowed by thicker walls, lower thermal conductivity, and a lower surface area—to-volume ratio than glass capillaries. Whereas the denaturation and annealing target temperatures were reached by samples in glass capillaries, samples in plastic capillaries fell short of these target temperatures by 6°–7°C. Rapid-cycle PCR was performed on two human genomic targets (APOE and ACVRL1) and one plasmid (pBR322) to amplify fragments of 225–300 bp in length with melting temperatures of 90.3°–93.1°C. Real-time amplification data, end-point melting curves, and end-point gel analysis revealed strong, specific amplification of samples in glass and complete amplification failure in plastic. Only the APOE target was successfully amplified by extending the denaturation and annealing times to 5 or 10 s. A 20 s holding period was necessary to reach target temperatures in plastic capillaries.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies