Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Control and Restrictions of a Hybrid Renewable Energy System Connected to the Grid: A Battery and Supercapacitor Storage Case

Tytuł:
Control and Restrictions of a Hybrid Renewable Energy System Connected to the Grid: A Battery and Supercapacitor Storage Case
Autorzy:
Jura Arkhangelski
Pedro Roncero-Sánchez
Mahamadou Abdou-Tankari
Javier Vázquez
Gilles Lefebvre
Temat:
hybrid renewable energy system (HRES)
power management
current control
grid synchronization
supercapacitor
battery
Technology
Źródło:
Energies, Vol 12, Iss 14, p 2776 (2019)
Wydawca:
MDPI AG, 2019.
Rok publikacji:
2019
Kolekcja:
LCC:Technology
Typ dokumentu:
article
Opis pliku:
electronic resource
Język:
English
ISSN:
1996-1073
Relacje:
https://www.mdpi.com/1996-1073/12/14/2776; https://doaj.org/toc/1996-1073
DOI:
10.3390/en12142776
Dostęp URL:
https://doaj.org/article/6188a1c818454abab067d6b0d88f4e6e  Link otwiera się w nowym oknie
Numer akcesji:
edsdoj.6188a1c818454abab067d6b0d88f4e6e
Czasopismo naukowe
This paper studies a Hybrid Renewable Energy System (HRES) as a reliable source of the power supply in the case of the connection to the grid. The grid connection imposes restrictions to the power delivered and harmonic content on the HRES. This causes the HRES to use multiple control systems and subsystems, as the normalization of the measurements, the current control, active harmonic compensation, synchronization, etc., described in this paper. Particular attention was paid to interactions in the storage system of the HRES. The durability of the HRES can be increased by the combination of the supercapacitors and batteries. This requires a power management solution for controlling the energy storage system. The aim of the supercapacitors is to absorb/inject the high-frequency fluctuations of the power and to smooth out the power of the batteries system of the HRES. This can be possible owing to the use of a low-pass second order filter, explained in this paper, which separates the high-frequency component of the storage system reference for the supercapacitor from the low-frequency component for the batteries system. This solution greatly increases the reliability and durability of the HRES.
Zaloguj się, aby uzyskać dostęp do pełnego tekstu.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies