Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Post-cataract outcomes in patients with noninfectious posterior uveitis treated with the fluocinolone acetonide intravitreal implant

Tytuł:
Post-cataract outcomes in patients with noninfectious posterior uveitis treated with the fluocinolone acetonide intravitreal implant
Autorzy:
Sheppard Jr JD
Nguyen QD
Usner DW
Comstock TL; Fluocinolone Acetonide Uveitis Study Group
Temat:
Ophthalmology
RE1-994
Źródło:
Clinical Ophthalmology, Vol 2012, Iss default, Pp 79-85 (2012)
Wydawca:
Dove Medical Press, 2012.
Rok publikacji:
2012
Kolekcja:
LCC:Ophthalmology
Typ dokumentu:
article
Opis pliku:
electronic resource
Język:
English
ISSN:
1177-5467
1177-5483
Relacje:
http://www.dovepress.com/post-cataract-outcomes-in-patients-with-noninfectious-posterior-uveiti-a9036; https://doaj.org/toc/1177-5467; https://doaj.org/toc/1177-5483
Dostęp URL:
https://doaj.org/article/6687c7d327ab4e0d8712e17d10f4d5af  Link otwiera się w nowym oknie
Numer akcesji:
edsdoj.6687c7d327ab4e0d8712e17d10f4d5af
Czasopismo naukowe
John D Sheppard Jr1, Quan Dong Nguyen2, Dale W Usner3, Timothy L Comstock3, for the Fluocinolone Acetonide Uveitis Study Group1Eastern Virginia Medical School, Norfolk, VA, USA; 2Wilmer Ophthalmological Institute, Johns Hopkins University, Baltimore, MD, USA; 3Bausch and Lomb Incorporated, Rochester, NY, USAPurpose: To describe visual acuity (VA) and inflammation following cataract surgery in eyes with noninfectious posterior uveitis (NIPU) that were being treated with a fluocinolone acetonide (FA) intravitreal implant compared with those that were not.Design: Post hoc, subgroup analysis of data from a 3-year, dose-masked, randomized, multicenter trial evaluating the FA implant for the treatment of NIPU.Participants and controls: The subset of eyes that underwent cataract surgery during the 3-year trial. Eyes were either implanted with a 0.59- or a 2.1-mg FA implant, or, in the case of affected fellow eyes, received standard-of-care local treatment.Main outcome measures: VA, anterior and posterior chamber inflammation at 1 and 3 months after surgery, and rate of uveitis recurrence and serious postoperative ocular adverse events.Results: Of 278 patients enrolled in the main trial, 132/142 phakic implanted eyes and 39/186 phakic non-implanted eyes underwent cataract surgery. Mean improvement in VA was significantly greater in implanted than non-implanted eyes at 1 (P = 0.0047) and 3 months (P = 0.0015) postoperatively; significantly fewer anterior chamber cells were seen in implanted than non-implanted eyes at 1 (P = 0.0084) and 3 months (P = 0.0002). Severity of vitreous haze was less in implanted than non-implanted eyes at 3 months postoperatively (P = 0.0005). The postsurgical uveitis recurrence rate was lower in implanted than non-implanted eyes (26.5% vs 44.4%; P = 0.0433). Glaucoma was reported in 19.7% of implanted eyes and no non-implanted eyes (P = 0.0008) postoperatively.Conclusion: In this post hoc subgroup analysis, eyes with NIPU treated with the FA intravitreal implant demonstrated better vision and less intraocular inflammation following cataract surgery than non-implanted eyes. Recurrent uveitic inflammation did not appear to be triggered by cataract surgery. Glaucoma occurred more frequently in implanted eyes.Keywords: cataract surgery, posterior chamber inflammation, glaucoma, intraocular pressure, visual acuity, steroid implant

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies