Effects of ambient temperature, airspeed, and wind direction on heat transfer coefficient for the human body by means of manikin experiments and CFD analysis

Tytuł:
Effects of ambient temperature, airspeed, and wind direction on heat transfer coefficient for the human body by means of manikin experiments and CFD analysis
Autorzy:
Gao Shan
Ooka Ryozo
Oh Wonseok
Temat:
Environmental sciences
GE1-350
Źródło:
E3S Web of Conferences, Vol 111, p 02041 (2019)
Wydawca:
EDP Sciences, 2019.
Rok publikacji:
2019
Kolekcja:
LCC:Environmental sciences
Typ dokumentu:
article
Opis pliku:
electronic resource
Język:
English
French
ISSN:
2267-1242
Relacje:
https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/37/e3sconf_clima2019_02041.pdf; https://doaj.org/toc/2267-1242
DOI:
10.1051/e3sconf/201911102041
Dostęp URL:
https://doaj.org/article/ecde8a09cbd541c5b2ef25e1f9ea0766  Link otwiera się w nowym oknie
Numer akcesji:
edsdoj.8a09cbd541c5b2ef25e1f9ea0766
Czasopismo naukowe
The purpose of this study is to confirm the effect of ambient temperature, airspeed, and wind direction on the heat transfer around the human body. A fixed surface temperature (33 °C) thermal manikin (TM) with 16 segments was employed. First, the manikin was placed in a climate chamber with ambient temperatures of 20 °C, 24 °C, and 28 °C, at airspeeds of less than 0.1 m/s to represent calm condition. Higher ambient temperatures led to a decrease in the convective heat transfer coefficient. The convective heat transfer coefficients for the sitting posture were higher than those of the standing posture. The same TM was then put in a wind tunnel with airspeeds ranging from 0.25 m/s to 1.4 m/s to represent forced convection. The TM was set to face upwind, downwind, and perpendicular to the wind (i.e., its right side facing the wind). Regression models for the convective heat transfer coefficient and airspeed for different wind directions and postures were derived. In contrast to the calm condition, the convective heat transfer coefficients for the sitting posture were lower than those for the standing posture. The convective heat transfer coefficients for the standing posture were largest when the TM was facing downwind, and smallest when the right side of the TM was facing the wind. To verify the results of the experiment, computational fluid dynamics (CFD) analysis was performed with conditions matching those of the experiment by using a computational TM with the same shape as that used in the experiment. The boundary conditions of the CFD analysis were set from the experiment. The CFD analysis results were consistent with the experimental data.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies