Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Improvement of Microstomia in Scleroderma after Carbon Dioxide Laser Treatment

Tytuł:
Improvement of Microstomia in Scleroderma after Carbon Dioxide Laser Treatment
Autorzy:
Imane Bennani
Raphael Lopez
Delphine Bonnet
Gregoire Prevot
Arnaud Constantin
Dominique Chauveau
Carle Paul
Cristina Bulai Livideanu
Temat:
Microstomia
Systemic sclerosis
Limited mouth opening
Carbon dioxide laser
Interincisal distance
Mouth Handicap in Systemic Sclerosis scale
Dermatology
RL1-803
Źródło:
Case Reports in Dermatology, Vol 8, Iss 2, Pp 142-150 (2016)
Wydawca:
Karger Publishers, 2016.
Rok publikacji:
2016
Kolekcja:
LCC:Dermatology
Typ dokumentu:
article
Opis pliku:
electronic resource
Język:
English
ISSN:
1662-6567
Relacje:
http://www.karger.com/Article/FullText/445821; https://doaj.org/toc/1662-6567
DOI:
10.1159/000445821
Dostęp URL:
https://doaj.org/article/8ea97eace6484c069e7fb4dccc9e0027  Link otwiera się w nowym oknie
Numer akcesji:
edsdoj.8ea97eace6484c069e7fb4dccc9e0027
Czasopismo naukowe
Limited mouth opening (LMO) is a frequent complication of systemic sclerosis (SS). Its management is complex and there are limited treatment options. We report four patients with SS and severe LMO [interincisal distance (IID) 2) laser. Pulsed CO2 laser treatment of the white lips was performed after all patients had signed a written informed consent in the absence of alternative treatment. Treatment was carried out under locoregional anaesthesia using a Sharplan 30C CO2 laser in the Silk Touch® resurfacing mode. One to three laser sessions were performed at intervals of 8-12 months between sessions. Assessments were performed at 3 and 12 months with measurement of the IID using a ruler, calculation of the Mouth Handicap in Systemic Sclerosis (MHISS) scale and global evaluation by the patients. Adverse events were also reported. In all four patients, an improvement in IID occurred 3 months after the first session with a mean gain of +5 mm (range: 2-7). At 12 months, a mean gain of +8.5 mm (range: 7-10) in IID was observed. The MHISS score decreased by a mean of -14 (range: 11-17). All patients showed improvement of lip flexibility or mouth opening, allowing better phonation and mastication and easier dental care. Adverse effects were transient erythema and/or dyschromia. CO2 laser appears to be effective and well tolerated in the improvement of LMO in SS.
Zaloguj się, aby uzyskać dostęp do pełnego tekstu.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies