Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Feasibility Analysis of a Membrane Desorber Powered by Thermal Solar Energy for Absorption Cooling Systems

Tytuł:
Feasibility Analysis of a Membrane Desorber Powered by Thermal Solar Energy for Absorption Cooling Systems
Autorzy:
Jonathan Ibarra-Bahena
Eduardo Venegas-Reyes
Yuridiana R. Galindo-Luna
Wilfrido Rivera
Rosenberg J. Romero
Antonio Rodríguez-Martínez
Ulises Dehesa-Carrasco
Temat:
membrane desorber
air gap membrane distillation
thermal solar energy
absorption cooling system
Technology
Engineering (General). Civil engineering (General)
TA1-2040
Biology (General)
QH301-705.5
Physics
QC1-999
Chemistry
QD1-999
Źródło:
Applied Sciences, Vol 10, Iss 3, p 1110 (2020)
Wydawca:
MDPI AG, 2020.
Rok publikacji:
2020
Kolekcja:
LCC:Technology
LCC:Engineering (General). Civil engineering (General)
LCC:Biology (General)
LCC:Physics
LCC:Chemistry
Typ dokumentu:
article
Opis pliku:
electronic resource
Język:
English
ISSN:
2076-3417
Relacje:
https://www.mdpi.com/2076-3417/10/3/1110; https://doaj.org/toc/2076-3417
DOI:
10.3390/app10031110
Dostęp URL:
https://doaj.org/article/db27bae99bf4428db812cbdb70d06279  Link otwiera się w nowym oknie
Numer akcesji:
edsdoj.b27bae99bf4428db812cbdb70d06279
Czasopismo naukowe
In absorption cooling systems, the desorber is a component that separates the refrigerant fluid from the liquid working mixture, most commonly completed by boiling separation; however, the operation temperature of boiling desorbers is generally higher than the low-enthalpy energy, such as solar, geothermal, or waste heat. In this study, we used a hydrophobic membrane desorber to separate water vapor from an aqueous LiBr solution. Influencing factors, such as the H2O/LiBr solution and cooling water temperatures, were tested and analyzed. With the experimental data, a solar collector system was simulated on a larger scale, considering a 1 m2 membrane. The membrane desorber evaluation shows that the desorption rate of water vapor increased as the LiBr solution temperature increased and the cooling water temperature decreased. Based on the experimental data from the membrane desorber/condenser, a theoretical heat load was calculated to size a solar system. Meteorological data from Emiliano Zapata in Mexico were considered. According to the numerical result, nine solar collectors with a total area of 37.4 m2 provide a solar fraction of 0.797. The membrane desorber/condenser coupled to the solar system can provide an average of 16.8 kg/day of refrigerant fluid that can be used to produce a cooling effect in an absorption refrigerant system.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies