Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Improving the Detection Ability of Inductive Micro-Sensor for Non-Ferromagnetic Wear Debris

Tytuł:
Improving the Detection Ability of Inductive Micro-Sensor for Non-Ferromagnetic Wear Debris
Autorzy:
Man Wang
Haotian Shi
Hongpeng Zhang
Dian Huo
Yucai Xie
Jun Su
Temat:
non-ferromagnetic debris
detection ability
inductance parameter
resistance parameter
excitation frequency
Mechanical engineering and machinery
TJ1-1570
Źródło:
Micromachines, Vol 11, Iss 12, p 1108 (2020)
Wydawca:
MDPI AG, 2020.
Rok publikacji:
2020
Kolekcja:
LCC:Mechanical engineering and machinery
Typ dokumentu:
article
Opis pliku:
electronic resource
Język:
English
ISSN:
2072-666X
Relacje:
https://www.mdpi.com/2072-666X/11/12/1108; https://doaj.org/toc/2072-666X
DOI:
10.3390/mi11121108
Dostęp URL:
https://doaj.org/article/aab77fbe828346ea9768afefceb389b5  Link otwiera się w nowym oknie
Numer akcesji:
edsdoj.b77fbe828346ea9768afefceb389b5
Czasopismo naukowe
The inductive debris sensor has been studied because of its wide application prospects in mechanical health monitoring. In order to ensure a high-precision detection performance, a comprehensive method to improve the detection sensitivity and detection ability of the inductive sensor for non-ferromagnetic metal debris is proposed. Based on the characteristics of the eddy current inside the metal, the change of the coil impedance caused by the metal debris is increased by enhancing the magnetic field strength and selecting the optimal excitation frequency. The impedance detection method involving inductance and resistance parameters is used to improve the detection limit of non-ferromagnetic metal debris. The experimental results verify that the magnetic field in the detection region can be enhanced by adding a silicon steel strip (paramagnetic material) in the central hole of the coil, thereby greatly improving the detection sensitivity of the inductive sensor, and the concentrated distribution of the magnetic field avoids the double-peak signals generated by a single particle. The characteristics of the signal amplitude of non-ferromagnetic debris with excitation frequency are studied. Higher inductance, resistance amplitudes, and signal-to-noise ratio (SNR) can be obtained by using a high-frequency alternating current. Compared with inductance parameter detection, resistance parameter detection can detect smaller non-ferromagnetic debris. Combining the detection results of the inductance and resistance parameters can effectively improve the sensor’s ability to detect non-ferromagnetic debris.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies