A novel coriolis mass flowmeter signal processing method based on adaptive notch filter and Hilbert transform

Tytuł:
A novel coriolis mass flowmeter signal processing method based on adaptive notch filter and Hilbert transform
Autorzy:
Shen Ting’ao
Chen Liwei
Huang Siyu
Zhang Peili
Temat:
Hilbert transform
Adaptive notch filter
Parameter estimation
Coriolis mass flowmeter
Flowrate measurement
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
Źródło:
Energy Reports, Vol 8, Iss , Pp 265-272 (2022)
Wydawca:
Elsevier, 2022.
Rok publikacji:
2022
Kolekcja:
LCC:Electrical engineering. Electronics. Nuclear engineering
Typ dokumentu:
article
Opis pliku:
electronic resource
Język:
English
ISSN:
2352-4847
Relacje:
http://www.sciencedirect.com/science/article/pii/S2352484722022260; https://doaj.org/toc/2352-4847
DOI:
10.1016/j.egyr.2022.10.312
Dostęp URL:
https://doaj.org/article/dba8378ff6fc443d88b52573bb2ae0c0  Link otwiera się w nowym oknie
Numer akcesji:
edsdoj.ba8378ff6fc443d88b52573bb2ae0c0
Czasopismo naukowe
Coriolis mass flowmeter has been widely used in the energy field, and the key of mass flowrate measurement is to calculate the frequency and phase difference of the signal accurately. Aiming at the poor measurement precision problem in Coriolis mass flowmeter, a novel Coriolis mass flowmeter signal processing method is presented based on adaptive notch filter and Hilbert transform. Firstly, the long time continuous frequency tracking and accuracy problem of adaptive notch filter is effectively solved, by introducing the idea of negative feedback control. Then, the frequency estimation results are used to judgment whether the whole data will be extended or not, which makes the length of data sequence close to or equal to an integer multiple of the period. And then, Hilbert transform is conducted to the extended signals. Finally, the phase difference can be obtained by utilizing the sinusoidal functions. Simulation results show that the proposed method has high frequency and phase difference estimation accuracy, and it can be used for real time flowrate measurement of flowmeter. Experimental tests validate that the precision of this method is less than 3‰, which is more than 2 times of that of the traditional method.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies