Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Assessment Indexes for Converter P-Q Control Coupling

Tytuł:
Assessment Indexes for Converter P-Q Control Coupling
Autorzy:
Panagis N. Vovos
Ioannis D. Bouloumpasis
Konstantinos G. Georgakas
Temat:
active and reactive power control
power coupling
power distribution lines
power electronics converters
power generation control
performance evaluation
Technology
Źródło:
Energies, Vol 13, Iss 5, p 1144 (2020)
Wydawca:
MDPI AG, 2020.
Rok publikacji:
2020
Kolekcja:
LCC:Technology
Typ dokumentu:
article
Opis pliku:
electronic resource
Język:
English
ISSN:
1996-1073
Relacje:
https://www.mdpi.com/1996-1073/13/5/1144; https://doaj.org/toc/1996-1073
DOI:
10.3390/en13051144
Dostęp URL:
https://doaj.org/article/bbbbfcca0bad4552ad30fbd9e5d964af  Link otwiera się w nowym oknie
Numer akcesji:
edsdoj.bbbbfcca0bad4552ad30fbd9e5d964af
Czasopismo naukowe
This work presents a concise methodology for the calculation of assessment indexes regarding the coupling between active and reactive power control observed on distribution level converters. First, the reader is introduced to the concept of power coupling; when, where and how it appears in power control of converters. A brief summary of the theory and formulation behind it is also included, together with relevant literature. Then, the methodology for the assessment of active and reactive power control performance of any grid-connected converter is presented. The impact of small control disturbances during a testing procedure is monitored, analyzed and converted to meaningful indexes, so that the type and level of coupling is quantified without putting the converter or the grid at risk. The efficiency of the methodology to assess the type and level of coupling is verified experimentally. This is done by assessing several power control approaches with different level of decoupling efficiency on the same power converter connected to a distribution grid. While the assessment is performed with safe, minimal disturbances, its exceptional accuracy is later confirmed by the level and type of coupling observed during significant power step changes.
Zaloguj się, aby uzyskać dostęp do pełnego tekstu.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies