Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Different Models of Dual-Energy Bone DXA Scanners: A Comparative Study

Tytuł:
Different Models of Dual-Energy Bone DXA Scanners: A Comparative Study
Autorzy:
Alexey V. Petraikin
Ekaterina S. Akhmad
Dmitry S. Semenov
Zlata R. Artyukova
Nikita D. Kudryavtsev
Fedor A. Petriaikin
Ludmila A. Nizovtsova
Temat:
dxa
dual-energy x-ray absorptiometry
densitometry
bone mineral density
osteoporosis
precision
relative error
Orthopedic surgery
RD701-811
Źródło:
Travmatologiâ i Ortopediâ Rossii, Vol 28, Iss 2, Pp 48-57 (2022)
Wydawca:
Vreden Russian Research Institute of Traumatology and Orthopedics, 2022.
Rok publikacji:
2022
Kolekcja:
LCC:Orthopedic surgery
Typ dokumentu:
article
Opis pliku:
electronic resource
Język:
Russian
ISSN:
2311-2905
2542-0933
Relacje:
https://journal.rniito.org/jour/article/viewFile/1731/pdf; https://doaj.org/toc/2311-2905; https://doaj.org/toc/2542-0933
DOI:
10.17816/2311-2905-1731
Dostęp URL:
https://doaj.org/article/be552223951d483b9312b3857453a234  Link otwiera się w nowym oknie
Numer akcesji:
edsdoj.be552223951d483b9312b3857453a234
Czasopismo naukowe
Background. Dual-energy X-ray absorptiometry (DXA) is an effective method for bone mineral density (BMD) and subcutaneous fat percentage estimation. The constant development of new densitometry techniques, the demographic change and the higher potential of artificial intelligence in healthcare enhance requirements for the high-quality measurements in DXA. This study aimed to develop a quality control method for DXA scanners and compare four DXA systems with different X-ray geometries and manufacturers when simulating fat-water environments. Methods. We evaluated the accuracy (relative error (%) and precision (CV%)) of the bone mineral density (BMD) measurements, performed by the four DXA scanners: 2 with narrow-angle fan beam (64- and 16-channel detectors (DXA-1, DXA-2)); 1 with wide-angle fan beam (DXA-3); 1 with pencil beam (DXA-4). We used a PHK (PHantom Kalium) designed to imitate spine. The PHK contained four vertebras filled with a K2HPO4 solution in various concentrations (50-200 mg/ml). The PHK also included paraffin patches (thickness 40 mm) to simulate the fat layer. Results. DXA-1 and DXA-2 demonstrated the best CV% ranged from 0.56% to 1.05%. The least % was observed when scanning PHK with fat layer on DXA-1 and DXA-2 (1.74% and 0.85%) and DXA-4 (1.47%). DXA-3 produced significantly lower BMD (= -14.56%, p = 0.000). After removing the fat layer, we observed reduction (p = 0.000) of BMD for DXA- 1 and DXA-2 (= -5.11% and -6.12% respectively) and weak deviation (p = 0.80) for DXA-4 (0.87%). For DXA-3, removal of the fat layer also resulted in a significant reduction in BMD ( = -16.44%, p = 0.000). The subcutaneous fat modeling showed that all these DXA systems automatically determine the percentage of fat in the scanned area with weak underestimation: for DXA-1, DXA-2 and DXA-4 the % were -5,9%, -6,3% and -2,3% respectively. CV% were 0.15%; 0.39%; 1.6%, respectively. Conclusions. We proved a significant underestimation of the BMD measurements across the entire range of simulated parameters for the DXA scanners when the model did not include the subcutaneous fat layer. All models demonstrated high accuracy in measuring the fat layer, with the exception of the DXA-3 model, which was not assessed in these studies.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies