Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Efficacy of lung volume optimization maneuver monitored by optoelectronic pletismography in the management of congenital diaphragmatic hernia

Tytuł:
Efficacy of lung volume optimization maneuver monitored by optoelectronic pletismography in the management of congenital diaphragmatic hernia
Autorzy:
G. Lista
I. Bresesti
F. Cavigioli
F. Castoldi
E. Lupo
A. LoMauro
A. Aliverti
Temat:
CDH
Lung volume
Ventilation strategy
Newborn
Opto-electronic plethysmography
Diseases of the respiratory system
RC705-779
Źródło:
Respiratory Medicine Case Reports, Vol 22, Iss C, Pp 133-136 (2017)
Wydawca:
Elsevier, 2017.
Rok publikacji:
2017
Kolekcja:
LCC:Diseases of the respiratory system
Typ dokumentu:
article
Opis pliku:
electronic resource
Język:
English
ISSN:
2213-0071
Relacje:
http://www.sciencedirect.com/science/article/pii/S2213007117302058; https://doaj.org/toc/2213-0071
DOI:
10.1016/j.rmcr.2017.07.013
Dostęp URL:
https://doaj.org/article/cf2c4c6856a74abcbafd4c7159718938  Link otwiera się w nowym oknie
Numer akcesji:
edsdoj.f2c4c6856a74abcbafd4c7159718938
Czasopismo naukowe
Newborns affected by congenital diaphragmatic hernia (CDH) need cardio-respiratory stabilization before undergoing surgical repair. Open lung strategy is a well-established approach to optimize lung volume in preterm infants with Respiratory Distress Syndrome (RDS), using both High Frequency Oscillatory Ventilation (HFOV) and Conventional Mechanical Ventilation (CMV). We report a case of left CDH with severe lung hypoplasia, managed applying open lung strategy in HFOV (pre-surgery period) and in Assist-Control with Volume Guarantee (post-surgery period), guided by SpO2 changes, TcPO2 and TcPCO2 monitoring. Opto-electronic plethysmography was used to measure end-expiratory chest wall volume changes (ΔEEcw) related to lung volume variations occurring during pressure changes. OEP confirmed the efficacy of using SpO2 and transcutaneous gas monitoring during this recruitment maneuver.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies