Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Yo-Yo Intermittent Recovery Level 1 Test for Estimation of Peak Oxygen Uptake: Use Without Restriction?

Tytuł:
Yo-Yo Intermittent Recovery Level 1 Test for Estimation of Peak Oxygen Uptake: Use Without Restriction?
Autorzy:
Schmitz, Boris
Pfeifer, Carina
Thorwesten, Lothar
Krüger, Michael
Klose, Andreas
Brand, Stefan-Martin
Temat:
RUNNING
EXERCISE tests
AEROBIC capacity
SPIROMETRY
EXERCISE
RESEARCH evaluation
OXYGEN consumption
HEART beat
PULMONARY gas exchange
LACTIC acid
LONGITUDINAL method
Źródło:
Research Quarterly for Exercise & Sport. Sep2020, Vol. 91 Issue 3, p478-487. 10p.
Czasopismo naukowe
Purpose: This study analyzed the physiological response during Yo-Yo Intermittent Recovery Level 1 (YYIR1) test and re-test by in-field ergospirometry and time-series analyses of respiratory parameters. Methods: Ten moderately trained males (23.4 ± 2.01 years, VO2peak= 56.81 ± 10.75 mL·kg-1·min-1) completed three running trials including two separate YYIR1 tests and an independent maximal performance running test with time-series analyses of gas exchange parameters. Physiological response was assessed during all tests by determination of blood lactate levels (including calculation of individual lactate threshold), heart rate, oxygen consumption and respiratory exchange ratio (RER). Results: Modeling of YYIR1 test mean VO2 uptake kinetics over all participants revealed that VO2 increased rapidly after the individual lactate threshold (11.49 ± 0.66 km∙h-1 at 3.83 ± 0.42 mmol∙L-1) was reached with ~95% VO2peak at ~50% of the test duration (test, VO250%= 95.17 ± 8.74% of VO2peak; re-test, VO250%= 96.78 ± 7.04% of VO2peak). However, and despite identical YYIR1 test performance (1568 ± 364.6 m vs. 1568 ± 449.7 m, CV = 4.59%), mean VO2peak during YYIR1 test was 8.81 ± 5.6% higher than YYIR1 re-test (p = .027). Importantly, correlation of VO2peak with YYIR1 test performance was weak (R2 = 0.28, p = .115). Conclusions: We conclude that the YYIR1 test should not be used to estimate VO2peak. Further studies on direct determination of gas exchange parameters during different YYI test variants are warranted. [ABSTRACT FROM AUTHOR]
Copyright of Research Quarterly for Exercise & Sport is the property of Routledge and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies