Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę ""Forman, Christoph"" wg kryterium: Autor


Wyświetlanie 1-11 z 11
Tytuł:
Fast TWIST with iterative reconstruction improves diagnostic accuracy of AVM of the hand.
Autorzy:
Huf VI; Department of Radiology, University Medical Center Regensburg, 93042, Regensburg, Germany. .
Fellner C; Department of Radiology, University Medical Center Regensburg, 93042, Regensburg, Germany.
Wohlgemuth WA; Interdisciplinary Center for Vascular Anomalies, University Clinic and Polyclinic of Radiology, University Hospital Halle, 06120, Halle (Saale), Germany.
Stroszczynski C; Department of Radiology, University Medical Center Regensburg, 93042, Regensburg, Germany.
Schmidt M; Siemens Healthcare, 91052, Erlangen, Germany.
Forman C; Siemens Healthcare, 91052, Erlangen, Germany.
Wetzl J; Siemens Healthcare, 91052, Erlangen, Germany.
Uller W; Department of Radiology, University Medical Center Regensburg, 93042, Regensburg, Germany.
Pokaż więcej
Źródło:
Scientific reports [Sci Rep] 2020 Oct 01; Vol. 10 (1), pp. 16355. Date of Electronic Publication: 2020 Oct 01.
Typ publikacji:
Journal Article; Research Support, Non-U.S. Gov't
MeSH Terms:
Arteriovenous Malformations/*diagnostic imaging
Hand/*blood supply
Hand/*diagnostic imaging
Magnetic Resonance Angiography/*methods
Adult ; Aged ; Female ; Humans ; Image Processing, Computer-Assisted ; Male ; Middle Aged ; Retrospective Studies
Czasopismo naukowe
Tytuł:
Feasibility of contrast-enhanced coronary artery magnetic resonance angiography using compressed sensing.
Autorzy:
Hirai K; Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan.
Kido T; Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan.
Kido T; Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan. .
Ogawa R; Department of Radiology, Saiseikai Matsuyama Hospital, 880-2, Yamanishi, Matsuyama, Ehime, 791-8026, Japan.
Tanabe Y; Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan.
Nakamura M; Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan.
Kawaguchi N; Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan.
Kurata A; Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan.
Watanabe K; Department of Cardiology, Saiseikai Matsuyama Hospital, 880-2, Yamanishi, Matsuyama, Ehime, 791-8026, Japan.
Yamaguchi O; Department of Cardiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan.
Schmidt M; Siemens Healthcare GmbH, Allee am Roethelheimpark 2, 91052, Erlangen, Germany.
Forman C; Siemens Healthcare GmbH, Allee am Roethelheimpark 2, 91052, Erlangen, Germany.
Mochizuki T; Department of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan.
Pokaż więcej
Źródło:
Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance [J Cardiovasc Magn Reson] 2020 Feb 13; Vol. 22 (1), pp. 15. Date of Electronic Publication: 2020 Feb 13.
Typ publikacji:
Journal Article; Multicenter Study
MeSH Terms:
Image Interpretation, Computer-Assisted*
Magnetic Resonance Angiography*
Magnetic Resonance Imaging, Cine*
Contrast Media/*administration & dosage
Coronary Angiography/*methods
Coronary Artery Disease/*diagnostic imaging
Coronary Vessels/*diagnostic imaging
Organometallic Compounds/*administration & dosage
Adult ; Aged ; Feasibility Studies ; Female ; Humans ; Japan ; Male ; Middle Aged ; Predictive Value of Tests ; Prospective Studies ; Reproducibility of Results ; Time Factors ; Workflow
Czasopismo naukowe
Tytuł:
Surveillance of abdominal aortic aneurysm using accelerated 3D non-contrast black-blood cardiovascular magnetic resonance with compressed sensing (CS-DANTE-SPACE).
Autorzy:
Zhu C; Department of Radiology and Biomedical Imaging, UCSF, 4150 Clement Street, San Francisco, CA, 94121, USA. .
Cao L; Department of Radiology and Biomedical Imaging, UCSF, 4150 Clement Street, San Francisco, CA, 94121, USA.; Department of Radiology, Xuanwu Hospital, Beijing, China.
Wen Z; Department of Radiology and Biomedical Imaging, UCSF, 4150 Clement Street, San Francisco, CA, 94121, USA. .; Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart, Lung and Blood Vessel Disease, Beijing, 100029, China. .
Ahn S; Siemens Healthcare, San Francisco, CA, USA.
Raithel E; Siemens Healthcare GmbH, Erlangen, Germany.
Forman C; Siemens Healthcare GmbH, Erlangen, Germany.
Hope M; Department of Radiology and Biomedical Imaging, UCSF, 4150 Clement Street, San Francisco, CA, 94121, USA.
Saloner D; Department of Radiology and Biomedical Imaging, UCSF, 4150 Clement Street, San Francisco, CA, 94121, USA.
Pokaż więcej
Źródło:
Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance [J Cardiovasc Magn Reson] 2019 Oct 28; Vol. 21 (1), pp. 66. Date of Electronic Publication: 2019 Oct 28.
Typ publikacji:
Journal Article; Research Support, N.I.H., Extramural; Validation Study
MeSH Terms:
Imaging, Three-Dimensional*
Magnetic Resonance Angiography*
Aorta, Abdominal/*diagnostic imaging
Aortic Aneurysm, Abdominal/*diagnostic imaging
Aged ; Aorta, Abdominal/physiopathology ; Aortic Aneurysm, Abdominal/physiopathology ; Humans ; Male ; Predictive Value of Tests ; Reproducibility of Results ; Time Factors ; Workflow
Czasopismo naukowe
Tytuł:
Evaluation of cerebral arteriovenous shunts: a comparison of parallel imaging time-of-flight magnetic resonance angiography (TOF-MRA) and compressed sensing TOF-MRA to digital subtraction angiography.
Autorzy:
Sakata, Akihiko
Fushimi, Yasutaka
Okada, Tomohisa
Nakajima, Satoshi
Hinoda, Takuya
Speier, Peter
Schmidt, Michaela
Forman, Christoph
Yoshida, Kazumichi
Kataoka, Hiroharu
Miyamoto, Susumu
Nakamoto, Yuji
Pokaż więcej
Temat:
MAGNETIC resonance angiography
STATISTICS
DIGITAL subtraction angiography
ARTERIOVENOUS fistula
SURGICAL arteriovenous shunts
ARTERIOVENOUS malformation
Źródło:
Neuroradiology; Jun2021, Vol. 63 Issue 6, p879-887, 9p
Czasopismo naukowe
Tytuł:
Highly undersampled peripheral Time-of-Flight magnetic resonance angiography: optimized data acquisition and iterative image reconstruction.
Autorzy:
Hutter, Jana
Grimm, Robert
Forman, Christoph
Hornegger, Joachim
Schmitt, Peter
Pokaż więcej
Temat:
MAGNETIC resonance angiography
MAGNETIC resonance imaging
COMPRESSED sensing
Źródło:
MAGMA: Magnetic Resonance Materials in Physics, Biology & Medicine; Oct2015, Vol. 28 Issue 5, p437-446, 10p
Czasopismo naukowe
Tytuł:
High-resolution 3D whole-heart coronary MRA: a study on the combination of data acquisition in multiple breath-holds and 1D residual respiratory motion compensation.
Autorzy:
Forman, Christoph
Piccini, Davide
Grimm, Robert
Hutter, Jana
Hornegger, Joachim
Zenge, Michael
Pokaż więcej
Temat:
MAGNETIC resonance angiography
CORONARY angiography
DATA acquisition systems
IMAGE quality in imaging systems
COMPRESSED sensing
THREE-dimensional imaging in biology
Źródło:
MAGMA: Magnetic Resonance Materials in Physics, Biology & Medicine; Oct2014, Vol. 27 Issue 5, p435-443, 9p
Czasopismo naukowe
Tytuł:
High resolution time-of-flight MR-angiography at 7 T exploiting VERSE saturation, compressed sensing and segmentation.
Autorzy:
Meixner, Christian R. (AUTHOR)
Liebig, Patrick (AUTHOR)
Speier, Peter (AUTHOR)
Forman, Christoph (AUTHOR)
Hensel, Bernhard (AUTHOR)
Schmidt, Manuel (AUTHOR)
Saake, Marc (AUTHOR)
Uder, Michael (AUTHOR)
Doerfler, Arnd (AUTHOR)
Heidemann, Robin M. (AUTHOR)
Schmitter, Sebastian (AUTHOR)
Nagel, Armin M. (AUTHOR)
Pokaż więcej
Źródło:
Magnetic Resonance Imaging (0730725X). Nov2019, Vol. 63, p193-204. 12p.
Czasopismo naukowe
Tytuł:
Comparison of compressed sensing and conventional coronary magnetic resonance angiography for detection of coronary artery stenosis.
Autorzy:
Ogawa, Ryo (AUTHOR)
Kido, Tomoyuki (AUTHOR)
Nakamura, Masashi (AUTHOR)
Tanabe, Yuki (AUTHOR)
Kurata, Akira (AUTHOR)
Schmidt, Michaela (AUTHOR)
Forman, Christoph (AUTHOR)
Komori, Yoshiaki (AUTHOR)
Watanabe, Kouki (AUTHOR)
Kido, Teruhito (AUTHOR)
Mochizuki, Teruhito (AUTHOR)
Pokaż więcej
Źródło:
European Journal of Radiology. Aug2020, Vol. 129, pN.PAG-N.PAG. 1p.
Czasopismo naukowe
    Wyświetlanie 1-11 z 11

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies