Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Przeglądasz jako GOŚĆ

Wyszukujesz frazę ""Lab-On-A-Chip Devices"" wg kryterium: Temat


Tytuł :
Multiple authentications of high-value milk by centrifugal microfluidic chip-based real-time fluorescent LAMP.
Autorzy :
Yu W; Institute of Quality Standard & Testing Technology for Agro-Products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing 100081, People's Republic of China.
Chen Y; Willingmed Corporation, 156 Jinghai Industrial Parkway, Daxing District, Beijing 100176, People's Republic of China; CapitalBio Corporation, 18 Life Science Parkway, Changping District, Beijing 102206, People's Republic of China.
Wang Z; Institute of Quality Standard & Testing Technology for Agro-Products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing 100081, People's Republic of China.
Qiao L; Institute of Quality Standard & Testing Technology for Agro-Products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing 100081, People's Republic of China.
Xie R; Institute of Quality Standard & Testing Technology for Agro-Products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing 100081, People's Republic of China.
Zhang J; Institute of Quality Standard & Testing Technology for Agro-Products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing 100081, People's Republic of China.
Bian S; CapitalBio Corporation, 18 Life Science Parkway, Changping District, Beijing 102206, People's Republic of China.
Li H; Institute of Quality Standard & Testing Technology for Agro-Products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing 100081, People's Republic of China.
Zhang Y; Willingmed Corporation, 156 Jinghai Industrial Parkway, Daxing District, Beijing 100176, People's Republic of China; CapitalBio Corporation, 18 Life Science Parkway, Changping District, Beijing 102206, People's Republic of China. Electronic address: .
Chen A; Institute of Quality Standard & Testing Technology for Agro-Products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing 100081, People's Republic of China. Electronic address: .
Pokaż więcej
Źródło :
Food chemistry [Food Chem] 2021 Jul 30; Vol. 351, pp. 129348. Date of Electronic Publication: 2021 Feb 20.
Typ publikacji :
Journal Article
MeSH Terms :
Food Quality*
Lab-On-A-Chip Devices*
Centrifugation/*instrumentation
Milk/*chemistry
Molecular Diagnostic Techniques/*instrumentation
Nucleic Acid Amplification Techniques/*instrumentation
Animals ; Cattle ; DNA Primers/genetics ; Female ; Milk/standards ; Time Factors
SCR Protocol :
LAMP assay
Czasopismo naukowe
Tytuł :
Development of an electrically responsive hydrogel for programmable in situ immobilization within a microfluidic device.
Autorzy :
AmbroŽič R; University of Ljubljana, Faculty of Chemistry and Chemical Technology, Večna pot 113, 1000 Ljubljana, Slovenia. .
Plazl I; University of Ljubljana, Faculty of Chemistry and Chemical Technology, Večna pot 113, 1000 Ljubljana, Slovenia. and Chair of Microprocess Engineering and Technology - COMPETE, University of Ljubljana, Večna pot 113, 1000 Ljubljana, Slovenia.
Pokaż więcej
Źródło :
Soft matter [Soft Matter] 2021 Jul 21; Vol. 17 (28), pp. 6751-6764.
Typ publikacji :
Journal Article
MeSH Terms :
Hydrogels*
Lab-On-A-Chip Devices*
Alginates ; Ferric Compounds ; Spectroscopy, Fourier Transform Infrared
Czasopismo naukowe
Tytuł :
Numerical simulation of critical particle size in asymmetrical deterministic lateral displacement.
Autorzy :
Rezaei B; Small Medical Devices, BioMEMS & LoC Lab, School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran 11155-463, Iran.
Moghimi Zand M; Small Medical Devices, BioMEMS & LoC Lab, School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran 11155-463, Iran. Electronic address: .
Javidi R; Small Medical Devices, BioMEMS & LoC Lab, School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran 11155-463, Iran.
Pokaż więcej
Źródło :
Journal of chromatography. A [J Chromatogr A] 2021 Jul 19; Vol. 1649, pp. 462216. Date of Electronic Publication: 2021 May 03.
Typ publikacji :
Journal Article
MeSH Terms :
Computer Simulation*
Lab-On-A-Chip Devices*
Microfluidic Analytical Techniques/instrumentation ; Particle Size
Czasopismo naukowe
Tytuł :
Galenic Lab-on-a-Chip concept for lipid nanocapsules production.
Autorzy :
Rolley N; MINT Lab, UNIV Angers, INSERM 1066, CNRS 6021, Université Bretagne Loire, Angers, France. .
Bonnin M
Lefebvre G
Verron S
Bargiel S
Robert L
Riou J
Simonsson C
Bizien T
Gimel JC
Benoit JP
Brotons G
Calvignac B
Pokaż więcej
Źródło :
Nanoscale [Nanoscale] 2021 Jul 15; Vol. 13 (27), pp. 11899-11912.
Typ publikacji :
Journal Article
MeSH Terms :
Lab-On-A-Chip Devices*
Nanocapsules*
Lipids ; Reproducibility of Results ; Scattering, Small Angle ; X-Ray Diffraction
Czasopismo naukowe
Tytuł :
Scalable mRNA and siRNA Lipid Nanoparticle Production Using a Parallelized Microfluidic Device.
Autorzy :
Shepherd SJ; Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States.
Warzecha CC; Gene Therapy Program, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States.
Yadavali S; Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States.
El-Mayta R; Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States.
Alameh MG; Department of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States.
Wang L; Gene Therapy Program, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States.
Weissman D; Department of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States.
Wilson JM; Gene Therapy Program, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States.
Issadore D; Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States.; Department of Electrical and Systems Engineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States.; Department of Chemical and Biomolecular Engineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States.
Mitchell MJ; Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States.; Abramson Cancer Center, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States.; Institute for Immunology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States.; Cardiovascular Institute, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States.; Institute for Regenerative Medicine, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States.
Pokaż więcej
Źródło :
Nano letters [Nano Lett] 2021 Jul 14; Vol. 21 (13), pp. 5671-5680. Date of Electronic Publication: 2021 Jun 30.
Typ publikacji :
Journal Article; Research Support, N.I.H., Extramural; Research Support, Non-U.S. Gov't; Research Support, U.S. Gov't, Non-P.H.S.; Research Support, U.S. Gov't, P.H.S.
MeSH Terms :
Lab-On-A-Chip Devices*
Nanoparticles*
Animals ; Lipids ; Mice ; RNA, Messenger ; RNA, Small Interfering/genetics
Czasopismo naukowe
Tytuł :
Recent innovations in cost-effective polymer and paper hybrid microfluidic devices.
Autorzy :
Zhou W; Department of Chemistry and Biochemistry, University of Texas at El Paso, 500 W University Ave., El Paso, TX 79968, USA. .
Dou M; Department of Chemistry and Biochemistry, University of Texas at El Paso, 500 W University Ave., El Paso, TX 79968, USA. .
Timilsina SS; Department of Chemistry and Biochemistry, University of Texas at El Paso, 500 W University Ave., El Paso, TX 79968, USA. .
Xu F; Bioinspired Engineering and Biomechanics Center (BEBC), The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, PR China.
Li X; Department of Chemistry and Biochemistry, University of Texas at El Paso, 500 W University Ave., El Paso, TX 79968, USA. and Border Biomedical Research Center, Biomedical Engineering, University of Texas at El Paso, 500 West University Ave., El Paso, TX 79968, USA and Environmental Science and Engineering, University of Texas at El Paso, 500 West University Ave., El Paso, TX 79968, USA.
Pokaż więcej
Źródło :
Lab on a chip [Lab Chip] 2021 Jul 13; Vol. 21 (14), pp. 2658-2683.
Typ publikacji :
Journal Article; Research Support, N.I.H., Extramural; Research Support, Non-U.S. Gov't; Research Support, U.S. Gov't, Non-P.H.S.; Review
MeSH Terms :
Lab-On-A-Chip Devices*
Microfluidic Analytical Techniques*
Cell Culture Techniques ; Cost-Benefit Analysis ; Microfluidics ; Polymers
Czasopismo naukowe
Tytuł :
A portable droplet microfluidic device for cortisol measurements using a competitive heterogeneous assay.
Autorzy :
Evans GWH; Mechanical Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, SO17 1BJ, UK. , University of Southampton, Southampton, SO17 1BJ, UK.
Bhuiyan WT; Mechanical Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, SO17 1BJ, UK. .
Pang S; National Measurement Laboratory (LGC), Queens Road, Teddington, TW11 0LY, UK.
Warren B; SouthWestSensor Ltd, 2 Venture Road, Chilworth, Southampton, SO16 7NP, England, UK.
Makris K; SouthWestSensor Ltd, 2 Venture Road, Chilworth, Southampton, SO16 7NP, England, UK.
Coleman S; SouthWestSensor Ltd, 2 Venture Road, Chilworth, Southampton, SO16 7NP, England, UK.
Hassan SU; Mechanical Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, SO17 1BJ, UK. .
Niu X; Mechanical Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, SO17 1BJ, UK. , University of Southampton, Southampton, SO17 1BJ, UK and SouthWestSensor Ltd, 2 Venture Road, Chilworth, Southampton, SO16 7NP, England, UK.
Pokaż więcej
Źródło :
The Analyst [Analyst] 2021 Jul 12; Vol. 146 (14), pp. 4535-4544.
Typ publikacji :
Journal Article
MeSH Terms :
Lab-On-A-Chip Devices*
Microfluidics*
Enzyme-Linked Immunosorbent Assay ; Humans ; Hydrocortisone ; Point-of-Care Systems
Czasopismo naukowe
Tytuł :
Neuronal circuits on a chip for biological network monitoring.
Autorzy :
Herreros P; Group of Optics, Photonics and Biophotonics (GOFB), Center for Biomedical Technology, Universidad Politécnica de Madrid, Madrid, Spain.; Group of Organ and Tissue on-a-chip and In-Vitro Detection, Health Research Institute of the Hospital Clínico San Carlos, Madrid, Spain.
Ballesteros-Esteban LM; Complex Systems Group & GISC, Universidad Rey Juan Carlos, Madrid, Spain.; Group of Biological Networks, Center for Biomedical Technology, Universidad Politécnica de Madrid, Madrid, Spain.
Laguna MF; Group of Optics, Photonics and Biophotonics (GOFB), Center for Biomedical Technology, Universidad Politécnica de Madrid, Madrid, Spain.; Group of Organ and Tissue on-a-chip and In-Vitro Detection, Health Research Institute of the Hospital Clínico San Carlos, Madrid, Spain.; Departamento de Física Aplicada e Ingeniería de Materiales, Escuela Técnica Superior de Ingenieros Industriales, Universidad Politécnica de Madrid, Madrid, Spain.
Leyva I; Complex Systems Group & GISC, Universidad Rey Juan Carlos, Madrid, Spain.; Group of Biological Networks, Center for Biomedical Technology, Universidad Politécnica de Madrid, Madrid, Spain.
Sendiña-Nadal I; Complex Systems Group & GISC, Universidad Rey Juan Carlos, Madrid, Spain.; Group of Biological Networks, Center for Biomedical Technology, Universidad Politécnica de Madrid, Madrid, Spain.
Holgado M; Group of Optics, Photonics and Biophotonics (GOFB), Center for Biomedical Technology, Universidad Politécnica de Madrid, Madrid, Spain.; Group of Organ and Tissue on-a-chip and In-Vitro Detection, Health Research Institute of the Hospital Clínico San Carlos, Madrid, Spain.; Departamento de Física Aplicada e Ingeniería de Materiales, Escuela Técnica Superior de Ingenieros Industriales, Universidad Politécnica de Madrid, Madrid, Spain.
Pokaż więcej
Źródło :
Biotechnology journal [Biotechnol J] 2021 Jul; Vol. 16 (7), pp. e2000355. Date of Electronic Publication: 2021 May 31.
Typ publikacji :
Journal Article
MeSH Terms :
Lab-On-A-Chip Devices*
Microfluidic Analytical Techniques*
Cell Culture Techniques ; Microfluidics ; Neurons
Czasopismo naukowe
Tytuł :
Optimizing pressure-driven pulsatile flows in microfluidic devices.
Autorzy :
Recktenwald SM; Dynamics of Fluids, Department of Experimental Physics, Saarland University, Saarbrücken, Germany. .
Wagner C; Dynamics of Fluids, Department of Experimental Physics, Saarland University, Saarbrücken, Germany. and Physics and Materials Science Research Unit, University of Luxembourg, Luxembourg, Luxembourg.
John T; Dynamics of Fluids, Department of Experimental Physics, Saarland University, Saarbrücken, Germany. .
Pokaż więcej
Źródło :
Lab on a chip [Lab Chip] 2021 Jun 29; Vol. 21 (13), pp. 2605-2613.
Typ publikacji :
Journal Article; Research Support, Non-U.S. Gov't
MeSH Terms :
Lab-On-A-Chip Devices*
Microfluidics*
Pulsatile Flow
Czasopismo naukowe
Tytuł :
A microfluidic device enabling deterministic single cell trapping and release.
Autorzy :
Chai H; State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing, China. .
Feng Y; State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing, China. .
Liang F; State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing, China. .
Wang W; State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing, China. .
Pokaż więcej
Źródło :
Lab on a chip [Lab Chip] 2021 Jun 29; Vol. 21 (13), pp. 2486-2494.
Typ publikacji :
Journal Article; Research Support, Non-U.S. Gov't
MeSH Terms :
Lab-On-A-Chip Devices*
Microfluidic Analytical Techniques*
Cell Separation ; Humans ; Models, Theoretical ; Single-Cell Analysis
Czasopismo naukowe
Tytuł :
Airway-On-A-Chip: Designs and Applications for Lung Repair and Disease.
Autorzy :
Bennet TJ; School of Biomedical Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada.; Centre for Blood Research, University of British Columbia, Vancouver, BC V6T 1Z4, Canada.
Randhawa A; School of Biomedical Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada.; Centre for Blood Research, University of British Columbia, Vancouver, BC V6T 1Z4, Canada.
Hua J; School of Biomedical Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada.; Centre for Blood Research, University of British Columbia, Vancouver, BC V6T 1Z4, Canada.
Cheung KC; School of Biomedical Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada.; Centre for Blood Research, University of British Columbia, Vancouver, BC V6T 1Z4, Canada.; Department of Electrical & Computer Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada.
Pokaż więcej
Źródło :
Cells [Cells] 2021 Jun 26; Vol. 10 (7). Date of Electronic Publication: 2021 Jun 26.
Typ publikacji :
Journal Article; Review
MeSH Terms :
Lab-On-A-Chip Devices*
Lung/*physiology
Lung Diseases/*pathology
Regeneration/*physiology
Respiratory Mucosa/*cytology
COVID-19/pathology ; COVID-19/therapy ; COVID-19/virology ; Cells, Cultured ; Extracellular Matrix/physiology ; Humans ; Lung/cytology ; Lung/pathology ; Lung Diseases/physiopathology ; Lung Diseases/therapy ; Models, Biological ; Respiratory Mucosa/pathology ; Respiratory Mucosa/physiology ; SARS-CoV-2/pathogenicity ; Tissue Culture Techniques/instrumentation ; Tissue Culture Techniques/methods
Czasopismo naukowe
Tytuł :
Ultrafast and Real-Time Nanoplasmonic On-Chip Polymerase Chain Reaction for Rapid and Quantitative Molecular Diagnostics.
Autorzy :
Kang BH; Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea.; KAIST Institute for Health Science and Technology (KIHST), Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea.
Lee Y; Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea.; KAIST Institute for Health Science and Technology (KIHST), Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea.
Yu ES; Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea.; KAIST Institute for Health Science and Technology (KIHST), Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea.
Na H; Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea.; KAIST Institute for Health Science and Technology (KIHST), Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea.
Kang M; Biomedical Engineering Research Center, Smart Healthcare Research Institute, Samsung Medical Center, Seoul 06351, Republic of Korea.; Department of Medical Device Management and Research, SAIHST (Samsung Advanced Institute for Health Sciences and Technology), Sungkyunkwan University, Seoul 06355, Republic of Korea.
Huh HJ; Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea.
Jeong KH; Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea.; KAIST Institute for Health Science and Technology (KIHST), Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea.
Pokaż więcej
Źródło :
ACS nano [ACS Nano] 2021 Jun 22; Vol. 15 (6), pp. 10194-10202. Date of Electronic Publication: 2021 May 19.
Typ publikacji :
Journal Article; Research Support, Non-U.S. Gov't
MeSH Terms :
COVID-19*
Lab-On-A-Chip Devices*
Humans ; Pathology, Molecular ; Real-Time Polymerase Chain Reaction ; SARS-CoV-2
Czasopismo naukowe
Tytuł :
Curcumin-Loaded Hybrid Nanoparticles: Microchannel-Based Preparation and Antitumor Activity in a Mouse Model.
Autorzy :
Hong W; Department of Pharmacy, Taizhou Municipal Hospital, Taizhou, 318000, People's Republic of China.; College of Pharmaceutical Science, Zhejiang University of Technology, Hangzhou, 310014, People's Republic of China.
Gao Y; College of Pharmaceutical Science, Zhejiang University of Technology, Hangzhou, 310014, People's Republic of China.
Lou B; College of Pharmaceutical Science, Zhejiang University of Technology, Hangzhou, 310014, People's Republic of China.
Ying S; College of Pharmaceutical Science, Zhejiang University of Technology, Hangzhou, 310014, People's Republic of China.
Wu W; College of Pharmaceutical Science, Zhejiang University of Technology, Hangzhou, 310014, People's Republic of China.
Ji X; College of Pharmaceutical Science, Zhejiang University of Technology, Hangzhou, 310014, People's Republic of China.
Yu N; College of Pharmaceutical Science, Zhejiang University of Technology, Hangzhou, 310014, People's Republic of China.
Jiao Y; College of Pharmaceutical Science, Zhejiang University of Technology, Hangzhou, 310014, People's Republic of China.
Wang H; Department of Pharmacy, Taizhou Municipal Hospital, Taizhou, 318000, People's Republic of China.
Zhou X; Department of Pharmacy, Taizhou Municipal Hospital, Taizhou, 318000, People's Republic of China.
Li A; Zhejiang Share Bio-Pharm Co., Ltd, Hangzhou, 310019, People's Republic of China.
Guo F; College of Pharmaceutical Science, Zhejiang University of Technology, Hangzhou, 310014, People's Republic of China.
Yang G; College of Pharmaceutical Science, Zhejiang University of Technology, Hangzhou, 310014, People's Republic of China.
Pokaż więcej
Źródło :
International journal of nanomedicine [Int J Nanomedicine] 2021 Jun 17; Vol. 16, pp. 4147-4159. Date of Electronic Publication: 2021 Jun 17 (Print Publication: 2021).
Typ publikacji :
Journal Article
MeSH Terms :
Lab-On-A-Chip Devices*
Curcumin/*chemistry
Curcumin/*pharmacology
Nanoparticles/*chemistry
Nanotechnology/*instrumentation
Animals ; Antineoplastic Agents/chemistry ; Antineoplastic Agents/pharmacokinetics ; Antineoplastic Agents/pharmacology ; Biological Availability ; Caproates/chemistry ; Cell Line, Tumor ; Curcumin/pharmacokinetics ; Drug Carriers/chemistry ; Humans ; Lactones/chemistry ; Mice ; Particle Size ; Polyethylene Glycols/chemistry ; Tissue Distribution
Czasopismo naukowe
Tytuł :
Advanced continuous-flow microfluidic device for parallel screening of crystal polymorphs, morphology, and kinetics at controlled supersaturation.
Autorzy :
Coliaie P; Department of Chemical Engineering, University of Illinois at Chicago, Chicago, IL 60607, USA. .
Kelkar MS; Center of Excellence for Isolation & Separation Technologies (CoExIST), Process R&D, AbbVie Inc., North Chicago, IL 60064, USA.
Langston M; Pharmaceutics Research - Analytical Development, Takeda Pharmaceuticals International Co., Cambridge, MA 02139, USA.
Liu C; Pharmaceutical Development, Biogen, Cambridge, MA 02142, USA.
Nazemifard N; Chemical Process Development, Takeda Pharmaceuticals International Co., Cambridge, MA 02139, USA.
Patience D; Pharmaceutical Development, Biogen, Cambridge, MA 02142, USA.
Skliar D; Chemical Process Development, Product Development, Bristol Myers Squibb Co., New Brunswick, NJ 08901, USA.
Nere NK; Department of Chemical Engineering, University of Illinois at Chicago, Chicago, IL 60607, USA. and Center of Excellence for Isolation & Separation Technologies (CoExIST), Process R&D, AbbVie Inc., North Chicago, IL 60064, USA.
Singh MR; Department of Chemical Engineering, University of Illinois at Chicago, Chicago, IL 60607, USA. .
Pokaż więcej
Źródło :
Lab on a chip [Lab Chip] 2021 Jun 15; Vol. 21 (12), pp. 2333-2342.
Typ publikacji :
Journal Article; Research Support, Non-U.S. Gov't
MeSH Terms :
Lab-On-A-Chip Devices*
Microfluidic Analytical Techniques*
Crystallization ; High-Throughput Screening Assays ; Kinetics ; Solutions
Czasopismo naukowe
Tytuł :
Evaluation of Tavakol et al.: Harnessing organs-on-a-chip to model tissue regeneration.
Corporate Authors :
2020 Till & McCulloch Meetings Compelling Communication Workshop Participants. Electronic address:
2020 Till & McCulloch Meetings Compelling Communication Workshop Participants
Źródło :
Cell stem cell [Cell Stem Cell] 2021 Jun 03; Vol. 28 (6), pp. 979-982.
Typ publikacji :
Journal Article; Comment
MeSH Terms :
Lab-On-A-Chip Devices*
Wound Healing*
Oligonucleotide Array Sequence Analysis
Czasopismo naukowe
Tytuł :
Microchip RT-PCR Detection of Nasopharyngeal SARS-CoV-2 Samples.
Autorzy :
Cojocaru R; Department of Molecular Biology and Biochemistry, Simon Fraser University, Burnaby, British Columbia.
Yaseen I; Department of Molecular Biology and Biochemistry, Simon Fraser University, Burnaby, British Columbia.
Unrau PJ; Department of Molecular Biology and Biochemistry, Simon Fraser University, Burnaby, British Columbia. Electronic address: .
Lowe CF; Division of Medical Microbiology and Virology, St. Paul's Hospital, Vancouver, British Columbia; Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, British Columbia.
Ritchie G; Division of Medical Microbiology and Virology, St. Paul's Hospital, Vancouver, British Columbia.
Romney MG; Division of Medical Microbiology and Virology, St. Paul's Hospital, Vancouver, British Columbia.
Sin DD; Centre for Heart Lung Innovation, St. Paul's Hospital, Vancouver, British Columbia; Department of Medicine (Respirology), University of British Columbia, Vancouver, British Columbia.
Gill S; Lumex Instruments Canada, Mission, British Columbia, Canada.
Slyadnev M; Lumex Instruments Canada, Mission, British Columbia, Canada.
Pokaż więcej
Źródło :
The Journal of molecular diagnostics : JMD [J Mol Diagn] 2021 Jun; Vol. 23 (6), pp. 683-690. Date of Electronic Publication: 2021 Mar 09.
Typ publikacji :
Journal Article; Research Support, Non-U.S. Gov't
MeSH Terms :
Lab-On-A-Chip Devices*
COVID-19/*diagnosis
COVID-19 Nucleic Acid Testing/*standards
RNA, Viral/*genetics
Real-Time Polymerase Chain Reaction/*standards
SARS-CoV-2/*genetics
Benchmarking ; COVID-19/epidemiology ; COVID-19 Nucleic Acid Testing/instrumentation ; COVID-19 Nucleic Acid Testing/methods ; Canada/epidemiology ; Humans ; Limit of Detection ; Nasopharynx/virology ; Point-of-Care Testing ; Reagent Kits, Diagnostic/supply & distribution
Czasopismo naukowe
Tytuł :
A simple and reversible glass-glass bonding method to construct a microfluidic device and its application for cell recovery.
Autorzy :
Funano SI; Laboratory for Integrated biodevice, Center for Biosystems Dynamics Research, RIKEN, 1-3 Yamadaoka, Suita, Osaka 565-0871, Japan. .
Ota N; Laboratory for Integrated biodevice, Center for Biosystems Dynamics Research, RIKEN, 1-3 Yamadaoka, Suita, Osaka 565-0871, Japan. .
Tanaka Y; Laboratory for Integrated biodevice, Center for Biosystems Dynamics Research, RIKEN, 1-3 Yamadaoka, Suita, Osaka 565-0871, Japan. .
Pokaż więcej
Źródło :
Lab on a chip [Lab Chip] 2021 Jun 01; Vol. 21 (11), pp. 2244-2254.
Typ publikacji :
Journal Article; Research Support, Non-U.S. Gov't
MeSH Terms :
Lab-On-A-Chip Devices*
Microfluidic Analytical Techniques*
Glass ; Microfluidics ; Polymers
Czasopismo naukowe
Tytuł :
Gut-on-a-chip: Mimicking and monitoring the human intestine.
Autorzy :
Marrero D; Instituto de Microelectrónica de Barcelona (IMB-CNM, CSIC), Campus UAB, Bellaterra, 08193, Barcelona, Spain; Universidad Autónoma de Barcelona (UAB), Bellaterra, 08193, Barcelona, Spain.
Pujol-Vila F; Instituto de Microelectrónica de Barcelona (IMB-CNM, CSIC), Campus UAB, Bellaterra, 08193, Barcelona, Spain.
Vera D; Instituto de Microelectrónica de Barcelona (IMB-CNM, CSIC), Campus UAB, Bellaterra, 08193, Barcelona, Spain; Universidad Autónoma de Barcelona (UAB), Bellaterra, 08193, Barcelona, Spain.
Gabriel G; Instituto de Microelectrónica de Barcelona (IMB-CNM, CSIC), Campus UAB, Bellaterra, 08193, Barcelona, Spain; Centro de Investigación Biomédica en Red en Bioingeniería Biomateriales y Nanomedicina (CIBER-BBN), Madrid, 50018, Spain.
Illa X; Instituto de Microelectrónica de Barcelona (IMB-CNM, CSIC), Campus UAB, Bellaterra, 08193, Barcelona, Spain; Centro de Investigación Biomédica en Red en Bioingeniería Biomateriales y Nanomedicina (CIBER-BBN), Madrid, 50018, Spain.
Elizalde-Torrent A; IrsiCaixa AIDS Research Institute, Hospital Germans Trias i Pujol, 08916, Badalona, Catalonia, Spain.
Alvarez M; Instituto de Microelectrónica de Barcelona (IMB-CNM, CSIC), Campus UAB, Bellaterra, 08193, Barcelona, Spain; Centro de Investigación Biomédica en Red en Bioingeniería Biomateriales y Nanomedicina (CIBER-BBN), Madrid, 50018, Spain. Electronic address: .
Villa R; Instituto de Microelectrónica de Barcelona (IMB-CNM, CSIC), Campus UAB, Bellaterra, 08193, Barcelona, Spain; Centro de Investigación Biomédica en Red en Bioingeniería Biomateriales y Nanomedicina (CIBER-BBN), Madrid, 50018, Spain. Electronic address: .
Pokaż więcej
Źródło :
Biosensors & bioelectronics [Biosens Bioelectron] 2021 Jun 01; Vol. 181, pp. 113156. Date of Electronic Publication: 2021 Mar 08.
Typ publikacji :
Journal Article; Review
MeSH Terms :
Biosensing Techniques*
Lab-On-A-Chip Devices*
Humans ; Intestines ; Microfluidics ; Oligonucleotide Array Sequence Analysis
Czasopismo naukowe
Tytuł :
High-throughput human DNA purification on a centrifugal microfluidic device for rapid forensic sex-typing.
Autorzy :
Van Nguyen H; Department of Chemical Engineering (BK21 FOUR Integrated Engineering Program), Kyung Hee University, Yongin, 17104, South Korea.
Seo TS; Department of Chemical Engineering (BK21 FOUR Integrated Engineering Program), Kyung Hee University, Yongin, 17104, South Korea. Electronic address: .
Pokaż więcej
Źródło :
Biosensors & bioelectronics [Biosens Bioelectron] 2021 Jun 01; Vol. 181, pp. 113161. Date of Electronic Publication: 2021 Mar 13.
Typ publikacji :
Journal Article
MeSH Terms :
Biosensing Techniques*
Lab-On-A-Chip Devices*
DNA/genetics ; Humans ; Molecular Diagnostic Techniques ; Nucleic Acid Amplification Techniques
SCR Protocol :
LAMP assay
Czasopismo naukowe
Tytuł :
Integration of microfluidic sample preparation with PCR detection to investigate the effects of simultaneous DNA-Inhibitor separation and DNA solution exchange.
Autorzy :
Nikdoost A; Department of Mechanical Engineering, York University, Toronto, ON, Canada.
Doostmohammadi A; Department of Mechanical Engineering, York University, Toronto, ON, Canada.
Romanick K; Precision Biomonitoring Inc., Guelph, ON, Canada.
Thomas M; Precision Biomonitoring Inc., Guelph, ON, Canada.
Rezai P; Department of Mechanical Engineering, York University, Toronto, ON, Canada. Electronic address: .
Pokaż więcej
Źródło :
Analytica chimica acta [Anal Chim Acta] 2021 May 22; Vol. 1160, pp. 338449. Date of Electronic Publication: 2021 Mar 26.
Typ publikacji :
Journal Article
MeSH Terms :
Lab-On-A-Chip Devices*
Microfluidics*
DNA/genetics ; Particle Size ; Polymerase Chain Reaction
Czasopismo naukowe

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies